background image

MQ42LOG1 

8 Piece Driftwood Log Set - For use with GT Glass Tray 

 

 

 

 

 
 

 

 
 

 

 
 
 

 

WARNING:

 

Failure to 

position the 

parts in 

accordance 

with these 

diagrams or 

failure to use 

only parts 

specifically 

approved with 

this appliance 

may result in 

property 

damage or 

personal injury.

 

PILOT 

24

All manuals and user guides at all-guides.com

Summary of Contents for MCVP42LP

Page 1: ...peg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada May 5 2015 Part 42MCVP MAN14 For Propane Horizontal installations the venting must be an additional one foot above the minimum vertical ri...

Page 2: ...or use with GT Glass Tray 24 MQ42LOG1 8 Piece Driftwood Log Set For use with M42LG Log Grate 25 MQ42LOG2 7 Piece Oak Log Set For use with GT Glass Tray 26 MQ42LOG2 7 Piece Oak Log Set For use with M42...

Page 3: ...emote ON OFF Variable HI LO and Fan 52 Electronic Ignition Lighting Instructions 53 VENTING Vent Termination 54 General Vent Installation 55 Installation of Side Wall Venting 55 Venting Routes And Com...

Page 4: ...and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety All Units WARNING WHEN THE...

Page 5: ...repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to ex...

Page 6: ...oom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electric...

Page 7: ...tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a minimum of four hours at a time w...

Page 8: ...imum 20 gauge Minimum of 1 2 DUROCK cement board this non combustible panel is ULC listed as a wall shield floor protector and fasten to the entire perimeter framing Use fiberglass mesh tape for all j...

Page 9: ...al Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to insure grounding Use...

Page 10: ...e to be covered with Non Combustibles e g Concrete Board for Flat Wall appearance Qty 4 Nailing Tabs are located on flue side of fireplace Nailing Tab Framing Stud Drywall Non Combustible Material eg...

Page 11: ...e These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand offs Vertical Venting in Cold Climates In...

Page 12: ...ur Appliance See Mantel Leg Clearances Instruction for the proper placement of fireplace MCVP42 Fireplace Dimensions ISLAND ALL UNITS MAY BE VENTED VERTICALLY PENINSULA 12 All manuals and user guides...

Page 13: ...ove the minimum vertical rise off the flue before going horizontal Framed fireplace opening 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot Vent Fra...

Page 14: ...UST BE NON COMBUSTIBLE It is also recommended to attach Non combustible facing to framing Combustibles i e Drywall may be installed flush with top of Fireplace Side facing to be installed to standoffs...

Page 15: ...to finish face of wall NOTE Drywall will be flush with fireplace face Step 3 A brick tile or other non combustible border may be applied over fireplace face to conceal border Nailing Tab Drywall Firep...

Page 16: ...k your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage of a Non Combustible Mantel is that it can begin at the top of the fireplace opening...

Page 17: ...of the appliance must be used Carpet may extend 1 inch above the floor of the appliance Minimum Ceiling Height from bottom of fireplace 61 Top from Stand offs 0 Top of 90 Bend in minimum Enclosure of...

Page 18: ...Hook lower clip onto glass door frame Press down and push upper clip under top glass door frame Screens shown locked in place Clips First install smaller end screen Then install side screens Clips To...

Page 19: ...to install Porcelain Liners WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage...

Page 20: ...d Units or Deflectors Decorative Units Refer to Baffle Removal Deflector Removal sections of manual 2 Orient tabs in upper firebox as shown 3 Insert Liner into Firebox 4 Bend Tabs down over Brick Line...

Page 21: ...nd screw first Replace 4 remaining screws ZCV42MCVP Deflector Removal Decorative Units To Remove Deflectors Remove 2 DT Screws holding each Deflector in place To Replace Deflectors Replace 2 DT Screws...

Page 22: ...red The following items can be used with the Glass Tray ULK3 Light Kit MQLOG1 MQLOG2 M42LOG3 RBCB1 Cannonballs VLBIT4 or VLBIT6 Decorative Glass MQSTONE MQROCK2 or MQROCK3 MQEMBER Refer to appropriate...

Page 23: ...ay with screws To Remove 1 Remove screws holding Grate Assemblies in place 2 Remove screws holding Grate Plate in place 3 Remove from firebox Contents of Kit 1 2 Log Grates 2 2 Large Bags 3 4 Lava Roc...

Page 24: ...6 8 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1...

Page 25: ...parts specifically approved with this appliance may result in property damage or personal injury 2 5 6 8 1 3 4 7 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in B...

Page 26: ...ailure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 5 4 3 2 1 6 7 P...

Page 27: ...s specifically approved with this appliance may result in property damage or personal injury 1 3 1 4 2 7 5 6 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in Burner...

Page 28: ...5 6 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 5...

Page 29: ...specifically approved with this appliance may result in property damage or personal injury 1 8 1 2 3 4 5 6 7 8 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in Burn...

Page 30: ...first NOTE When using a remote control the 51 UHS Box must be used Batteries for Remote Receiver can be changed by lifting 51 UHS up through opening 51 UHS can be inserted removed from beneath firepl...

Page 31: ...or plug black and red transformer wires together if 120V receptacle will be switch controlled REFER TO COMPONENT LOCATIONS SECTION OF MANUAL FOR TRANSFORMER PLACEMENT Please follow the current ANSI N...

Page 32: ...r your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wiring errors can c...

Page 33: ...placed directly on Burner and on Glass Tray MQ Ember can be placed directly on Burner Only Lava Rock Supplied with Base Unit CANNOT be placed on Burner Place Lava Rock in channel in front of Glass Tra...

Page 34: ...on Burner Tube and Burner Tray 15lbs on Glass Tray 25lbs Max total MQG5W Decorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5B Decorative Ember Glass Black MQG5ZG Decorative Glass...

Page 35: ...lations If sooting occurs change position of or remove affected objects MQEMBER To be placed directly on Burner and Burner Ports Place these glowing ember chunks randomly May be used with or without o...

Page 36: ...an angle of between 15 and 30 degrees 3 Swing door up and pull top latches over door lip at each corner 4 Replace Access Cover below Glass Door 30 15 WARNING Wait until unit is COMPLETELY cool before...

Page 37: ...val of Large Glass Doors 1 Remove the door by unlatching the 2 top latches Simply place 2 fingers in the grooves and pull and lift upward slightly 2 Once the top of the door is unlatched pull it outwa...

Page 38: ...that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of th...

Page 39: ...ide of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter button every 5 seconds unti...

Page 40: ...millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator i...

Page 41: ...caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at least once a month and insp...

Page 42: ...onversion and Hi Lo valve regulator by following instructions supplied with the Conversion Kit Refer to Gas Specifications Chart for inlet pressures and input ratings Clock meter to verify input rate...

Page 43: ...of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instructi...

Page 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44 All manuals and user guides at all guides com...

Page 45: ...ner Removal instructions above to remove burner Remove fourteen 14 screws around edge of Burner Pan Carefully work the burner pan loose lift the assembly upward to remove it from the firebox cavity In...

Page 46: ...odule Fan Control Module UHS Box Cover Backup Battery Pack Modulating Servo Motor Is an add on valve component that permits HI LO functionality to be controlled by the remote Contrary to this feature...

Page 47: ...ey The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until th...

Page 48: ...e Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62 1001 P168si Orifice Pil...

Page 49: ...Configuration 1 Basic Manual HI LO and Manual ON OFF Capabilities 49 All manuals and user guides at all guides com...

Page 50: ...nal For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown in the figure bel...

Page 51: ...d by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams below IPI System EGTM Receiver Mod...

Page 52: ...Configuration 3 Remote ON OFF Variable HI LO Lights and Fan NOTE FAN IS NOT AVAILABLE ON 42MCVP UNITS ULK LIGHT KIT 52 All manuals and user guides at all guides com...

Page 53: ...NSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This fireplace is equipp...

Page 54: ...paved sidewalk or a paved driveway located on public property 7 feet 2 1m minimum 3 M Clearance above highest point of exit on roof 18 inches 45cm N Clearance to perpendicular wall 24 inches 60 cm Rec...

Page 55: ...f vent see the Framing Your Gas Fireplace section Cut a hole through the wall allowing for a 12 x 12 inside diameter in combustible walls for wall thimble or a 9 diameter hole in a non combustible wal...

Page 56: ...bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe dist...

Page 57: ...n the future Wall Thimble mount plate will be smaller than Termination Plate as a running change has been implemented Wall Thimble may need to be trimmed on outside mount plate to be completely hidden...

Page 58: ...all Thimble 15 3 4 13 5 16 1 3 16 Termination New Wall Thimble Old Termination 13 3 4 13 5 16 3 16 New Wall Thimble New Termination Wall Thimble 13 3 4 New Termination Old Wall Thimble Termination Ter...

Page 59: ...le to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge lay on top of the shingl...

Page 60: ...horizontal venting Straight through roof support configuration b Flex bend configuration c Termination mounting 43ft Z58VT Restrictor Remove for Runs Under 15 Feet 60 All manuals and user guides at a...

Page 61: ...permitted NOTE MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION Downward vertical vent runs are permitted however Cold Climate Switch Standing Pilot Mode must not be used Refer to your appliance manu...

Page 62: ...8 Flex Kit 5 8 Dia x 4 Unexpanded 8 Expanded Z58FK20 Flex Kit 5 8 Dia x 10 Unexpanded 20 Expanded Kits are complete with spring stand offs silicone ZDV5FC Flex Connector 5 Diameter ZDV8FC Flex Connect...

Page 63: ...e MP42CSSS Child Safety Screen Small Door Glass 42HB 310 Tempered Glass for Decorative Units 42HB 311 Ceramic Glass for Heater Rated Units 42MCVP 315T Tempered Glass for Decorative Units 42MCVP 315C C...

Page 64: ...Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 3600 B139...

Page 65: ...residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or application of the unit or...

Reviews: