Installation Instructions

Listed Certified for USA. and Canada

Certified to: ANSI Z21.88-2002/CSA-2.33-2002, CAN/CGA 2.17-1991, CSA P.4.1-02

Listed Direct Vent Gas Fired Free Standing Room Heater

Model Number FDV200 - FDV200P

Stock #’s: FDV200N, FDV200LP, FDV200PN, FDV200PLP

“Free Standing”

Direct Vent Gas Stove

Printed in Canada September 17, 2007  Part # 200-MAN

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.  This appliance is not
convertible for use with other gases, unless a certified kit is used.

A Division of R-Co. Inc.

2340 Logan Ave., Winnipeg, Manitoba, Canada  R2R 2V3

Ph: (204) 632-1962

Read this complete manual before beginning installation.

These instructions must be kept with the unit for future reference.

FOR YOUR SAFETY

Warning: 

Improper installation, alteration, service or maintenance can cause

property damage, personal injury or loss of life. Refer to this manual.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.

Do not store or use gasoline or other flammable vapors and liquids in the

vicinity of this or any other appliance.

What To Do If You Smell Gas

Do not try to light any appliance.

Extinguish any open flame.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbour’s phone.

If you can not reach your gas supplier, call the fire department.

Summary of Contents for FDV200LP

Page 1: ...n of R Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Read this complete manual before beginning installation These instructions must be kept with the unit for future reference...

Page 2: ...ory However due to the high temperature silicone components the paint will cure when heat is applied to the appliance as it is first used The following information applies to the curing process to get...

Page 3: ...1 Log assembly 12 Optional fan kit installation 13 Millivolt system lighting burner control 14 Vent termination 15 General venting information 16 Vent pipe assembly 19 Horizontal vent installation 19...

Page 4: ...nstallation of appliance or venting For required venting components see venting installation in appropriate section of this manual 4 THE FDV200N FDV200PN FDV200LP and FDV200PLP MAY BE INSTALLED IN MAN...

Page 5: ...or ignition of clothing 3 Children should be carefully supervised when they are in the same room as your fireplace appliance 4 Under no circumstances should this appliance be modified Any parts that...

Page 6: ...l comply with NFPA 720 2005 Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall a Be powered by the same electrical circuit as the applia...

Page 7: ...he minimum size of Alcove is Depth 30 Height 55 5 Width 52 5 THE FOLLOWING MINIMUM DISTANCES TO COMBUSTIBLES MUST BE OBSERVED TO ENSURE SAFE OPERATION OF YOUR STOVE A B C D E F Minimum distance to com...

Page 8: ...SIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equ...

Page 9: ...from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing Control co...

Page 10: ...burner areas This appliance should not be used as drying rack for clothing nor should Christmas stockings or decorations be hung near it Under no circumstances should any solid fuels wood paper cardbo...

Page 11: ...Reverse steps 1 2 to re install door REPLACING OF CERAMIC GLASS Follow Removal of Glass Door then clean all materials from door frame Using a high temperature sealant temperature resistant to 500 F 2...

Page 12: ...n the long branch of Log 2 onto notched area of Log 1 Step 3 Place Log 3 into position as shown in picture and slide Log 3 forward up to the locating tabs 3A 3B Do not place log on top of tabs Step 4...

Page 13: ...unit reaches operating temperature in approximately 10 to 15 minutes the fan will turn on The fan can be switched off if desired by turning the switch fully counter clockwise 6 Once the fan has start...

Page 14: ...lot screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA 16...

Page 15: ...rance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requirements check local codes V NOTE Clearances are to the edge of terminal plate...

Page 16: ...2 from top of horizontal pipes 1 on all other existing pipes REMEMBER THAT A 1 4 VERTICAL RISE IS REQUIRED FOR EVERY 12 OF HORIZONTAL RUN Venting terminal shall not be recessed into a wall or siding I...

Page 17: ...mum stove performance HOW TO USE THE VENT TABLE 1 Determine the height of the system and the number of elbows required 2 Use the Venting Chart to determine the maximum horizontal distance allowed Tota...

Page 18: ...ure sealant MIL PAC SEALANT IS RECOMMENDED to the pipe and secure it with the 4 screws washers If two pieces of 4 flex pipe are to be joined the joint must be siliconed and secured with screws Before...

Page 19: ...his may be unavoidable is when installing the vent terminal Note Do not remove or move spacer springs attached to 4 inner flex pipe these must be used to assure an 1 1 4 air gap between 4 and 7 pipes...

Page 20: ...AL VENTING AIR INTAKE PLATE ADJUSTMENT NOTE Unit comes preset for vertical venting under 15 feet Follow these instructions when venting exceeds 15 feet vertical 1 Locate the 3 x 1 4 hex screws and usi...

Page 21: ...de an offset in order to avoid cutting of joists and to clear other obstructions When using 45 elbows an elbow support is required directly above the highest elbow When installing a bend in a joist ar...

Page 22: ...set Support ZDVFS Firestop Spacer ZDVRS Roof Support ZDVSS Siding Shield ZDVWT Wall Thimble Horizontal Venting ZDV48GP Galvanized Pipe 7 Dia x 48 Vertical Installations ZDV4FP8 Flex Pipe 4 Diameter 4...

Page 23: ...SSEMBLED 199 713 1001 P714SI PILOT TOP CONVERTIBLE NG ASSEMBLED 199 714 1001 P633SI VALVE NOVA LP Hl LO 0820633 or 651 1001 P634SI VALVE NOVA NG Hl LO 0820634 or 652 1001 P216SI THERMOCOUPLE 290 216 F...

Page 24: ...t the valve from one type of fuel to the other Step 8 Check for gas leaks around the pilot burner tube and face of valve Step 9 Attach conversion label to label plate on bottom of unit writing informa...

Page 25: ...of the injector 2 and rotate it counter clockwise until it is free of the injector journal 3 5 Verify that the new injector is proper for the application The injector size is stamped on the side of th...

Page 26: ...als at wall switch If burner comes on replace defective Switch ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generato...

Page 27: ...th service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoe...

Reviews: