Burner System Maintenance
It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This
operation should be performed by your dealer or a qualified technician.
-CAUTION-
Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all
electrical connections to the appliance. Allow the appliance to cool to room temperature. Note
that the pilot assembly may be hot in an intermittent or standing-pilot system—even if the main
burner was never on. Exercise caution when working within the area.
-ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN-
Monthly Flame Inspection
It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems
with the burner tube. The pilot flame should also be inspected monthly to ensure proper operation.
Flame should appear similar to the above picture.
Conversion Kit Instructions – PART A
Kit Number
Description
Pilot Orifice
Burner Orifice
Brass (1000-255)
Brass Nipple
Air Shutter
Hi/Lo Regulator
3624HB -CKLP
3628HB -CKLP
3632HB -CKLP
LP Conversion
-Millivolt-
1001-P167SI
#30
(977.167)
#53
#52
#51
1000-253closed
1000-253closed
1000-P201VE
Fully Open
Fully Open
5/16”
1001-P202SI
(0.907.202)
3624HB -CKNG
3628HB -CKNG
3632HB -CKNG
NG Conversion
-Millivolt-
1001-P165SI
#51
(977.165)
#42
#37
#36
1000-253closed
1000-253closed
1000-P201VE
1/8”
7/32”
3/16”
1001-P201SI
(0.907.201)
3624HB -CKLPI
3628HB -CKLPI
3632HB -CKLPI
LP Conversion
-IPI -
1001-P168SI
#35
(977.168)
#53
#52
#51
1000-253closed
1000-253closed
1000-P201VE
Fully Open
Fully Open
5/16”
1002-P014SI
(0.907.014)
3624HB -CKNGI
3628HB -CKNGI
3632HB -CKNGI
NG Conversion
- IPI -
1001-P166SI
#62
(977.166)
#42
#37
#36
1000-253closed
1000-253closed
1000-P201VE
1/8”
7/32”
3/16”
1002-P016SI
(0.907.016)
Refer to “
Gas Specifications Chart
” for inlet pressures and input ratings. Clock meter to verify input rate. Place conversion label
as close to converted gas control as possible. Refer to lighting instructions to verify the normal operating sequence of the ignition
system. IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK
TESTING.
35
Summary of Contents for HBZDV36
Page 29: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 29...
Page 38: ...Gas Conversion for Modulator PART C WARNING WARNING 38...
Page 41: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 41...
Page 42: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 42...
Page 43: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 43...