Kingsman Fireplaces FP2085 Manual Download Page 22

OPERATING  INSTRUCTIONS

 

 

 

 

Upon completing the gas line connection, a small amount 

of air will be in the lines.  When first lighting the burner, it 

will take a few minutes for the lines to purge themselves 

of this air.  Once the purging is complete, the burner will 

light and operate as indicated in the instruction manual. 

Subsequent lighting of the appliance will not require such 

purging.

 

WARNING:

  Read  and  follow  the  Safety  and  Lighting 

Instructions page  in  this  manual  and  on  labels  on  the 

appliance. 

IF  YOU  DO  NOT  FOLLOW  THESE 

INSTRUCTIONS  PRECISELY,  A  FIRE  OR 

EXPLOSION  MAY  RESULT  AND  YOU  MAY  BE 

SERIOUSLY  INJURED!

 

 

MAINTENANCE INSTRUCTIONS

 

 

 

 

1.  T

he appliance should be inspected before initial use 

and  inspected  and  cleaned  at  least  annually  by  a 

qualified field service person.

 

 

2. Tampering is 

DANGEROUS

 and voids all warranties. 

If  the  burner  or  any  other component is found to be 

faulty,  it  must  be  replaced  prior  to  operation  of  the 

appliance with an approved component. Replacement 

burner must be as specified in the manual.

 

 

3.   To  obtain proper operation, it  is  imperative  that the 

burner flame characteristics  are steady, not lifting or 

floating.  Check the burner flame patterns with

 

Log Placement Instructions Section.

 

4.  Periodically remove the logs and examine the burner.

 

If  dirty, clean with a soft  brush.   Also  examine the 

area around the burner air shutter.  Any dirt or lint in this 

area should be removed.   This will ensure long life and 

trouble free operation.  Re-install the logs as shown in 

the log placement instructions.   When the appliance is 

put  back in  service, check the  burner flame patterns 

with Log Placement Instructions Section.

 

 

5.  Periodically check the hose  connecting the LP-gas 

cylinder to ensure it is not damaged in any way.

 

 

 

HIGH ELEVATION  INSTALLATION 

 

 

 

 

U.L.  Listed gas  fireplaces are tested and approved for 

elevations from 0 to 4,500 feet in Canada and U.S.A.

 

 

When installing this fireplace at an elevation above 4,500 

feet (in Canada), check with local authorities.

 

 

Consult   your   local   gas   utility   for   assistance in 

determining the proper orifice for your location.

 

CLEANING 

 

 

It is recommended to annually inspect and clean the unit to 

prevent malfunction and / or sooting. This operation should 

be performed by your dealer or a qualified technician. 

Carefully remove media (log set, Rocks, Glass, etc.). Gloves 

are recommended. 

Warning:

 Turn off Unit and allow to cool before cleaning. 

Only a qualified service technician should service and repair 

appliance. 

• Do not use cleaning fluids to clean logs. 

• Use a soft bristle brush or a vacuum with brush 

attachment. 

• Vacuum loose particles and dust from burner and valve 

• Inspect Burner Plate, Pilot, Valve, and Mixing Sleeve for 

spider webs or other blockages. 

• Replace media. Refer to the appropriate page in this 

manual for proper placement of contents, such as logs. 

 

22

Summary of Contents for FP2085

Page 1: ...se Only Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may...

Page 2: ...y and its operation including remote control operation if included is fully explained to and understood by the customer Important Information About Outdoor Fireplaces Before you build in this applianc...

Page 3: ...C85 Placement Instructions 14 Accessories for Your Fire Pit Bola Fire Bowls 15 24OBT MANCP Control Panel for FP2085T Fire Pits in Custom Enclosures 16 FP20SSRT Stainless Steel Ring Dimensions Accessor...

Page 4: ...eplaced prior to operating the appliance 11 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional se...

Page 5: ...Within a partial enclosure that includes an overhead cover and no more than two side walls 3 These side walls may be parallel as in a breezeway or at right angles to each other 4 Within a partial encl...

Page 6: ...minimum enclosure dimensions of 32 1 2 x 39 1 2 I D The top of enclosure must be of a non combustible material such as concrete board or wonder board 2 Clearance to combustible side wall is 24 minimu...

Page 7: ...ish on top of Wonder Board Do not use any combustible materials to finish top e g wood or plastic products 4 You must have an opening in the enclosure to have access to the on off valve 5 A minimum of...

Page 8: ...D Inside corners of shields should not touch combustible wall Shield must extend 3 past end of firepit Fig 1 Ref E 4 Note Firepit cabinet or other structures must NOT obstruct wall shield air space on...

Page 9: ...and make sure it is tight NOTE Fuel Supply line must not come into contact with surfaces having temperatures in excess of 140 F LP gas cylinder must be kept a minimum of 4 5 feet from the appliance Yo...

Page 10: ...can be opened without the use of tools Designs using a cover to gain access to the cylinder and cylinder valve shall be provided with handles or equivalent at a minimum of 180 degrees apart to facilit...

Page 11: ...fice into Air Shutter 5 Re attach Orifice Retainer Bracket to Burner Tray 6 Connect LP Hose and Regulator to Valve Assembly WARNING This conversion kit shall be installed by a qualified service agency...

Page 12: ...sition the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 15 BRASS CAP ORIFICE PRIMARY...

Page 13: ...accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 15 BRASS CAP ORIFICE PRIMARY AIR 1 4 NATURAL GAS...

Page 14: ...p the gas connection make sure that logs are not broken Identify the logs using the pictures below and place logs as indicated lining up with mounting pegs in logs STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 T...

Page 15: ...1 2 holes for drainage Fire Pit Bowl for FP2085T Round Fire Pit Valve Igniter Mount Box KINGSMAN OUTDOOR FIRE BOWLS FOR THE 2085T FIRE PIT Fire Bowl Includes Valve Igniter Mount Box 1 4 Lava Rock 10...

Page 16: ...e Valve Control Panel is 2 7 16 tall x 7 1 2 wide The Control Panel is inserted from the inside of the enclosure and set in place by tightening the 2 screws on the back of the Control Panel Assembly B...

Page 17: ...as Valve Control Knob and Igniter Button from the Fire Pit 2 Align the 2 round holes in the Stainless Steel Trim Ring with the Gas Valve and the Igniter on the Fire Pit and lower it into place 3 Repla...

Page 18: ...s FPB30TBT FPB30SGT Place Trim Ring over concrete bowl Screws are not required FPB32SGT Place Trim Ring over concrete bowl Tighten screws until they touch the concrete bowl DO NOT OVER TIGHTEN SCREWS...

Page 19: ...ly mist the surface every 6 months to check the water repellency Friction will wear away product more quickly leaving the fabric unprotected If this is the case such areas can be spot treated to renew...

Page 20: ...AGS 30 35LBS 6 7 BAGS MQG5B 1 2 Black Glass 5LBS 20LBS 4 BAGS 20LBS 4 BAGS 30 35LBS 6 7 BAGS MQG10C 1 4 Reflective Bronze Glass 10 LBS 20LBS 2 BAGS 20LBS 2 BAGS 30 35LBS 3 4 BAGS MQG10B 1 4 Black Glas...

Page 21: ...va Rock Supplied with Fire Pit 1 4 Lava Rock is used as Base Reflective Bronze Glass 20LBS MQSTONE with Lava Rock Base 10LBS MQSTONE with Bronze Glass Base 20LBS NOTE MQSTONE Requires a Glass or Lava...

Page 22: ...o examine the area around the burner air shutter Any dirt or lint in this area should be removed This will ensure long life and trouble free operation Re install the logs as shown in the log placement...

Page 23: ...reach your gas supplier call the re department Manual Valve with Push Button Ignition 1 STOP Read the safety information above 2 Remove the top cover 3 Find the manual gas control valve and push butto...

Page 24: ...s Steel Flex Connector 16 Qty 2 for FP2085NT Qty 1 for FP2085LPT 3 8 Stainless Steel Flex Connector 10 Qty 1 for FP2785LPT FL 8 24OB PHP1003 Thermocouple 9 4000 P963VE 3 8 Tube OD x 3 8 Male Pipe 10 2...

Page 25: ...07 Flat Lid for FP2785T FP20SSRT Stainless Steel Ring Fits FP2085NT FP2085LPT 24OBT MANCP Control Panel for FP2085NT FP2085LPT Round Fire Pits in custom enclosures OUTDOOR FIRE BOWLS FOR THE 2085T FIR...

Page 26: ...areas to help clear the area of residual gas before attempting to relight the appliance Natural gas is lighter than atmospheric air and will tend to rise and collect in higher areas while propane is...

Page 27: ...y conditions are not recommended for operation of the appliance as flames are being blown out of the combustion area and can be very hazardous causing personal or property damage Also if the flame is...

Page 28: ...nd or handling charges associated with any repair or replacement pursuant to this limited warranty will be your responsibility In this warranty the word installation means original installation We wil...

Reviews: