TROUBLE SHOOTING
• On installation please do not fix the
lamp under a roof or under trees, as
the lamp can light up during daylight
hours.
• If your lamp suddenly stops working,
the bulb or fuse could be defective or
there may have been a failure in the
electrical circuit. Please contact a
qualified electrician.
• Your lamp may not work satisfactorily
if it is placed in such a way that the
field of detection is not walked
through. Please ensure the detection
area is tested every now and again.
• If the temperature difference between
the object to be detected and the
surrounding area is too small (in the
summer for example) then your lamp
will react later. The range of detection
is then
10
metres instead of the
normal
12
metres for example.
10
mins. Turn the control clockwise to
increase the lighting period and
anti-clockwise to reduce the lighting
period.
Daylight Control
The daylight control adjusts the level of
daylight the infrared detector becomes
activated at, so that it can detect. Turn
the control clockwise to decrease the
lighting value so the light will come on
later in the evening. Turn the control
anti-clockwise to increase the lighting
value so the light will come on earlier in
the evening.
Sensitivity Control
The sensitivity control adjusts the
sensitivity of the detector. Turn the
control clockwise to increase sensitivity
and anti-clockwise to decrease it.
TESTING
By setting the time and daylight controls
to fully anti-clockwise a daylight walk-by
test can be performed to check operation
in daylight after the initial installation.
Field of Detection
The field of detection of the infrared
lamp can be adjusted
30
O
vertically and
30
O
horizontally.
The horizontal
120
O
detection
range can be
reduced or
expanded, see
Fig.
4
&
5
, to
reduce any false
detections caused
by movements
from neighbouring
grounds.
The best detection
is obtained by
approaching the
field of detection
perpendicular
to its axis. See Fig.
6
If the field of
detection is
approached
in the direction
of its axis, the
infrared detector
will, in some
cases, respond
later, See Fig
7
.
TECHNICAL DATA
Power Source:-
220 - 240V AC 50Hz
Max Lighting
Load:
400W
class C Xenon Tube
Detection Angle:
120
dgrees (fan shaped)
Detection Range:
12
M (adjustable)
Time Delay:
From
9
secs to 10 mins
(adjustable)
Light Sensitivity:
30
Lux (adjustable)
Power cord:
H
05
RN-F
3
G
1.0
mm
2
Glass:
177
x
140
x
5
mm
INSTALLER -
Please pass instruction manual
onto the owner of the unit
Please keep these instructions for future reference.
GUARANTEE
Is
s
u
e
n
o
:
7
0
3
1
7
4
WEST ROAD . HARLOW
ESSEX . CM
20 2
BG . UK
W W W. G R E E N B R O O K . C O . U K
Your KingShield Xenon Floodlight with PIR is
guaranteed for
12
months from
the date of purchase.
This does not affect your statutory rights.
TXPIR400 Instructions:Layout 1 3/5/13 11:13 Page 2