TROUBLE SHOOTING

• On installation please do not fix the

lamp under a roof or under trees, as

the lamp can light up during daylight

hours.

• If your lamp suddenly stops working,

the bulb or fuse could be defective or

there may have been a failure in the

electrical circuit. Please contact a

qualified electrician.

• Your lamp may not work satisfactorily

if it is placed in such a way that the

field of detection is not walked

through. Please ensure the detection

area is tested every now and again.

• If the temperature difference between

the object to be detected and the

surrounding area is too small (in the

summer for example) then your lamp

will react later. The range of detection

is then

10

metres instead of the

normal

12

metres for example.

10

mins. Turn the control clockwise to

increase the lighting period and

anti-clockwise to reduce the lighting

period.

Daylight Control

The daylight control adjusts the level of

daylight the infrared detector becomes

activated at, so that it can detect. Turn

the control clockwise to decrease the

lighting value so the light will come on

later in the evening. Turn the control

anti-clockwise to increase the lighting

value so the light will come on earlier in

the evening.

Sensitivity Control

The sensitivity control adjusts the

sensitivity of the detector. Turn the

control clockwise to increase sensitivity

and anti-clockwise to decrease it.

TESTING

By setting the time and daylight controls

to fully anti-clockwise a daylight walk-by

test can be performed to check operation

in daylight after the initial installation.

Field of Detection

The field of detection of the infrared

lamp can be adjusted

30

O

vertically and

30

O

horizontally.

The horizontal

120

O

detection

range can be

reduced or

expanded, see

Fig.

4

&

5

, to

reduce any false

detections caused

by movements

from neighbouring

grounds.

The best detection

is obtained by

approaching the

field of detection

perpendicular

to its axis. See Fig.

6

If the field of

detection is

approached

in the direction

of its axis, the

infrared detector

will, in some

cases, respond

later, See Fig

7

.

TECHNICAL DATA

Power Source:-

220 - 240V AC 50Hz

Max Lighting

Load:

400W

class C Xenon Tube

Detection Angle:

120

dgrees (fan shaped)

Detection Range:

12

M (adjustable)

Time Delay:

From

9

secs to 10 mins

(adjustable)

Light Sensitivity:

30

Lux (adjustable)

Power cord:

H

05

RN-F

3

G

1.0

mm

2

Glass:

177

x

140

x

5

mm

INSTALLER -

Please pass instruction manual

onto the owner of the unit

Please keep these instructions for future reference.

GUARANTEE

Is

s

u

e

n

o

:

7

0

3

1

7

4

WEST ROAD . HARLOW
ESSEX . CM

20 2

BG . UK

[email protected]

W W W. G R E E N B R O O K . C O . U K

Your KingShield Xenon Floodlight with PIR is

guaranteed for

12

months from

the date of purchase.

This does not affect your statutory rights.

TXPIR400 Instructions:Layout 1  3/5/13  11:13  Page 2

Reviews: