HHO CARBON CLEANER 6.0 OPERATION MANUAL
17
8. Notice
8.1- The machine power input cable should be reliable connection, the machine should be
fixed installation, free move should be prohibited.
8.2- The gas pipe connection should be properly sealed, prevent air leakage.
8.3- The working medium of the machine is carbon cleaning solution and electricity. The
power supply should be single-phases, 220V, please take care your device.
8.4- Pure water will be consumed during carbon cleaning, when display water adding tips,
after finishing carbon cleaning, please add 4 Liter pure water to water tank of
the machine.
8.5- If appear engine flameout during carbon cleaning, please process according to
The Operation Introduction of Engine Flameout (For more details, please read Annex3).
8.6- Regularly blowing dust inside the machine using the compressed air machine once
a month. Replacing the electrolyte and cleaning the electrolytic cell for twelve month.
9. Maintenance of the Machine
(The Introduction of Electrolytic Cell’s Cleaning and Electrolyte’s Replacing)
9.1- Turn off the Power Switch.
9.2- Put the machine in outdoors.
9.3- Refer to the “Annex4: The operation introduction of adding solution in the first
time”, remove the water level sensor in the electrolytic cell, expose the filling opening.
9.4- Open the drainage valve under the electrolytic cell, forward and back shake the
machine during drainage process, try to get rid of the dirt.
9.5- Close the valve when the liquid flow out totally.
9.6- Add water for the electrolytic cell until it left 10cm from the filling opening to the water
level.
9.7- Repeat the steps from 9.4-9.6 five times, until the exhaust liquid is clean.
9.8- According “ Annex4: The operation introduction of adding solution in the first time” to
add the electrolyte for eletrolytic cell. Electrolyte replacement is done.