![Kinghome GJC05BK-A6NRNC5A Owner'S Manual Download Page 37](http://html1.mh-extra.com/html/kinghome/gjc05bk-a6nrnc5a/gjc05bk-a6nrnc5a_owners-manual_1970311037.webp)
Where electrical components are being changed, they shall be fit for the purpose
and to the correct specification. At all times the manufacturer’s maintenance and
service guidelines shall be followed. If in doubt, consult the manufacturer’s
technical department for assistance.
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the circuit
until it is satisfactorily dealt with. If the fault cannot be corrected immediately
but it is necessary to continue operation, an adequate temporary solution shall
be used. This shall be reported to the owner of the equipment so all parties
are advised.
Initial safety checks shall include:
During repairs to sealed components, all electrical supplies shall be disconnected
from the equipment being worked upon prior to any removal of sealed covers, etc.
If it is absolutely necessary to have an electrical supply to equipment during servicing,
^ "
possibility of sparking;
" ] *
recovering or purging the system;
The following checks shall be applied to installations using FLAMMABLE
REFRIGERANTS:
containing parts are installed;
"
obstructed;
*
checked for the presence of refrigerant;
= " >=
signs that are illegible shall be corrected;
unlikely to be exposed to any substance which may corrode refrigerant containing
components, unless the components are constructed of materials which are
inherently resistant to being corroded or are suitably protected against being
so corroded.
Checks to the refrigeration equipment
Checks to electrical devices
Repairs to sealed components
%