Installation
- DO NOT wire/fit a plug to this appliance. The appliance
must be electrical connected to a fused fixed spur, which is
fitted with a 13Amp fuse.
- All fittings must be installed by a competent person in
accordance with the current IET Wiring Regulations
(BS7671). If in doubt, consult a qualified electrician.
- This product is suitable for use in living areas, and Bathroom
(dry) outside Zones and zone 2 only (see diagram below
and current IET Wiring Regulations for details). It is not
suitable for Bathroom Zones 0 and 1. If being fitted in a
bathroom a 30mA RCD must be used. This appliance
does not come fitted/supplied with a fused plug.
- Always refer to the Reference Drawing for Bathroom
Installation.
Note : the below drawing is for reference only.
- Full details can be found in the current IET Wiring
Regulations (BS7671).
0.6m
0.6m
ZONE
2
Window
recess
(DRY) OUTSIDE ZONES
ZONE
2
ZONE
1
2.25m
Ceilin
g
ZONE
0
IP24: THIS PRODUCT IS SUITABLE FOR BATHROOMS
(DRY) OUTSIDE ZONES AND ZONE 2
IMPORTANT : Please follow the safety advice set out on pages 3 to 5.
Summary of Contents for 3663602914389
Page 26: ...26 MAX 300 mm 1 2 3 Installation ...
Page 30: ......
Page 57: ...27 MAX 300 mm 1 2 3 Installation ...
Page 60: ......
Page 86: ...26 1 2 3 Instalacja Maks 300 mm ...
Page 88: ......
Page 112: ...24 1 2 3 Не более 300 мм Установка ...
Page 114: ......
Page 140: ...26 1 2 3 MAX 300 mm Instalare ...
Page 142: ......
Page 168: ...26 MAX 300 mm 1 2 3 Instalación ...
Page 170: ......
Page 196: ...26 1 2 3 MAX 300 mm Instalação ...
Page 198: ......
Page 224: ...26 1 2 3 Maks 300 mm Kurulum ...