background image

   

ELECTRIC SHOCK  OR FIRE HAZARD

 

                                          

!

 

!

 

Figure 3 

2

 

 

WHF INSTALLATION INSTRUCTIONS 

 

     CAUTION! 

      Turn OFF all electrical power  

to install heater 

Rating Label Location 

Total Amps 

Minimum AWG. Wire 

Size (Copper 

Circuit Breaker or 

Fuse Size 

0 thru 12 

#14 

15 amp 

12.1 thru 16 

#12 

20 amp 

16.1 thru 24 

#10 

30 amp 

Minimum Clearances for heater:  

Table 1 

Front 

TOP 

BOTTOM 

SIDES 

36 in 

12 in 

4 in 

6 in 

0.9 m 

30.5 cm 

10.2 cm 

15.2 cm 

Selecting A Location For Your Heater: 

DO NOT install less than 6” (15cm) from vertical side 

walls or open edge of door. This heater must have an 

unrestricted airflow. DO NOT select a location where it 

is likely to be blocked by furniture, curtains, etc. Be 

sure the location selected allows sufficient space for the 

heater as shown by Table 1. DO NOT locate this heater 

in an area where combustible vapors, gases liquids, or 

excessive lint, dust or moisture is present. 

 

 

 

 

 

 

 

 

The wire and breaker sizing chart will give a general rule 

of installation size.  Consult an electrician if you are not 

knowledgeable about wiring codes. 

 

Wire and Breaker Sizing: 

 

        

Table 2 

 

 

 

 

 

 

 

 

WIRING: Branch Circuit Connection 

1.  Connect heater only to the voltage, amperage and 

frequency specified on the nameplate. 

2.  Wiring procedures and connections shall be in ac-

cordance with all National and local codes having 

jurisdiction. 

3.  Set the bag containing the grille and packet with 

two (2) grille screws aside. 

4.  Loosen mounting screw and remove fan heater as-

sembly. 

5.  A knockout of 1/2 inch conduit size (7/8 inch / 

2.2cm) is provided in the back and side of the heater 

for power to enter. Provide proper strain relief con-

nectors for your wire entering the wallbox. 

6. 

Install wallbox a minimum of 6” from vertical side-
walls and 4” above floor.  

The front edge of wall 

can MUST extend 1/2” beyond finished wall sur-

face.

 

7.  Secure wallbox to the 2 x 4 studs using the two (2) 

holes on the side of the wallbox. Secure to wall stud 

on opposite side if required. 

8.  Connect supply wires, attach ground feed wire to 

the green ground wire with wire nuts. 

9.  Reinstall heater assembly into wallbox with screw at 

top of interior. 

10. Install grille securely with screws provided in pack-

et. Do not over tighten. 

11. Test unit by turning thermostat up past room tem-

perature. You will see a puff of smoke as the ele-

ments are energized and the fan turns on. This is a 

normal burn off of manufacturing lubricants and will 

dissipate in 5 minutes. 

12. Heater will continue to run until the room tempera-

ture you set is reached and then turn itself off until 

the temperature drops again. 

 

CAUTION - High temperature.

 

Risk of fire

, keep electri-

cal cords, drapery, furnishings, and other combusti-

bles at least 3 feet (0.9 m) from the front of the 

heater as well as away from the side and rear. To 

reduce the risk of fire, do not store or use gasoline or 

other flammable vapors and liquids in the vicinity of the 

heater. 

   

 

   

Figure 2 

Wiring Diagram                                     Figure 5 

Zero clearance to insulation. 

Figure 4 

!

 

DANGER 

Reviews: