background image

Test Strips

Pool

Strips

Test

and

Spa

Setting Control Dial

• 

 

 Do not add shock in or near the skimmer or into the Sparco

Cycler as it could damage equipment, risk potential explosion
or discolor your pool surface.

• 

  Add a stabilizer or condi-

tioner to the pool at the begin-
ning of the season if the sta-
bilizer level is below 20 ppm.
This will prevent chlorine burn
off. Follow manufacturer's
directions carefully.

• 

 Insert chamber into Sparco Cycler.

(Follow directions for replacing  a
chamber on Page 6.)

• 

 Replace cap and set the control dial on the Sparco Cycler.

 

(Follow directions for setting dial below.)

Start-up and Operation

12

 Hour Pump Run Time

24

 Hour Pump Run Time

PUMP SIZE

                    

        PUMP SIZE

2.5

          2

3.5

3

1

3

2.5

2

3.5

          3

2.5

2

2.5

2

1

3

4.5

          3.5

3

2.5

3

2.5

2

1.5

NR

          4.5

3.5

3

3.5

3

2.5

2

POOL SIZE

  3/4 hp         1 hp

1 1/2 hp

2 hp

3/4 hp

1 hp

1 1/2 hp

2 hp

NR

          5

4.5

3.5

NR

3.5

3

2.5

3

          2.5

2

3.5

2

3.5

3

2.5

*

*

*

*

*

*

*

*

NR

NR

*

*

Dial settings based on 1.5 ppm.
    Bypass installation recommended. See Special Installations on page 23.
NR -This pump size is not recommended for this size pool.

     7,000          (18')

     9,000          (21')

    12,000         (24')

    18,000

    25,000

    Gallons   Diameter

    30,000

RECOMMENDED FLOW
RATES:

 Above ground 20-60 gpm

 In ground 20-80 gpm

1. Set control dial by matching up the parameters of your pool on the chart below. This is a starting point
only and may need to be adjusted to fit your individual pool needs. See below for adjusting directions.

• 

 

Shock the pool with

chlorine to rid water of all
contaminants before
beginning. Follow
manufacturer's directions

4.  Use the
handle end of
cap tool if the
dial is hard to
turn.

IMPORTANT: 

 Pump run

times less than 8 hours could
result in under chlorination
due to inadequate flow
through the system.

3.  After day one, adjust the
dial up by 1/2 increment if the
free chlorine reading has
dropped or down by 1/2
increment if the reading has
risen. Continue this process
each day until the reading
stabilizes at your desired level
between 1.0- 3.0 ppm.

2.  For the first
week or so, test
the water daily for
free chlorine.

1.

2.

3.

4.

4

 

Remember to adjust dial by 1/2

increments only.  Higher than
suggested settings could result
in over chlorination and/or
bleached pool surfaces.

AUTOMATIC

WATER

TREATMENT

SYSTEM

Summary of Contents for SPARCO CYCLER

Page 1: ...Sparco Cycler Pool Care for Above Ground or In Ground Pools INSTRUCTION MANUAL CYCLER MODEL 5510 ...

Page 2: ...l O Rings 6 Replacing Cap O Ring 6 Replacing Knob 6 Winterizing 7 Parts List 7 In Ground In Line Installation 8 Above Ground Filter Installation 9 Above Ground Base Installation 10 For Proper Performance 11 Warranty Back Page For information on King Technology s entire product line visit our website at www kingtechnology com 2 ...

Page 3: ...turer s directions A dirty filter will slow the flow of water which could hamper proper circulation After your pool is up and running smoothly continue to test your water for pH total alkalinity and chlorine and maintain its balance by adding any necessary adjustment products see your dealer for details Before beginning with any pool care program you must first balance your pool water Take a water...

Page 4: ... 23 NR This pump size is not recommended for this size pool 7 000 18 9 000 21 12 000 24 18 000 25 000 Gallons Diameter 30 000 RECOMMENDED FLOW RATES Above ground 20 60 gpm In ground 20 80 gpm 1 Set control dial by matching up the parameters of your pool on the chart below This is a starting point only and may need to be adjusted to fit your individual pool needs See below for adjusting directions ...

Page 5: ...cap by hand only DO NOT OVERTIGHTEN DO NOT USE CAP TOOL TO TIGHTEN CAP FOR REMOVAL ONLY Turn off pump Turn dial to Minimum This reduces the flow of water into the unit when the cap is open so isolation valves are unnecessary Turn chamber over and shake slightly until tablets fall into tower areas Avoid sparks open flame or smoking when handling the chamber Insert chamber into Sparco Cycler lining ...

Page 6: ...iers find the snap ring tail located at approximately the five o clock position under the control dial Pull down and out of the groove Using a large screwdriver loosen the control dial Carefully pry the dial until it pulls out Insert the non lipped end of snap ring into the groove opening beginning at the 5 o clock position and push it up so that it threads itself around the control dial Using a s...

Page 7: ...GRAM PARTS LIST REF PART NUMBER DESCRIPTION QTY REQ 1 2 01 22 9412 Cap w O Ring 1 2 01 22 9920 Cap O Ring 1 3 N A Body 1 4 01 22 9480 Pressure Relief Valve 1 5 6 7 01 22 9441 Control Dial with O Rings 1 6 7 01 22 9450 Control Dial O Ring Set 1 8 9 01 22 9941 Knob with O Ring 1 10 01 22 8870 Cap Control Dial Tool 1 11 01 22 9970 Silicone Lubricant 1 12 01 22 9980 Chamber Cutting Tool 1 Remove chamb...

Page 8: ... NOT OVER TIGHTEN Following PVC cement directions brush PVC cement on ends of pipe and the inside of bushings Insert PVC pipe into bushings Hold in place 5 to 10 seconds to bond Installing a corrosion resistant check valve is recommended Hacksaw Do NOT install an in line Sparco Cycler off line Install after all equipment and as far as possible from heater Do NOT install in copper pipe as chemical ...

Page 9: ...rovided with filter Pipe Wrench Two 2 threaded by 1 1 2 threaded bushings Following pipe thread sealant directions brush sealant on filter threads Screw a bushing into each port of Sparco Cycler and hand tighten Completely tighten turning 1 to 2 revolutions with wrench DO NOT OVERTIGHTEN DO NOT USE TAPE as the threads on these units are not suitable for this use and leaking or bushing failure coul...

Page 10: ...LS NEEDED Pipe Thread Sealant Two Hose Adapters 1 1 2 X 1 1 2 X 1 1 4 Two Sections of 1 1 2 Flex Hose one provided with filter For better stability Sparco Cycler may be mounted on a base using Phillips pan head screws Screwdriver Wrench Two 2 Threaded by 1 1 2 Threaded Bushings Following pipe thread sealant directions brush sealant on to Sparco Cycler threads in both ports Brush sealant on the thr...

Page 11: ...ets to a larger size to decrease back pressure or smaller size to increase back pressure Contact your dealer to have your back pressure tested to ensure it is between 3 and 8 psi 2 Recommended flow rates for in ground unit is 20 80 gpm 3 Determine possible high flow situations that require a special installation such as A Water flow is higher than 80 gpm B In floor cleaner is included with pool C ...

Page 12: ...ool dealer or distributor for further information concerning shock treatments B Control dial settings in excess of the recommended setting levels for trichlor can result in excess sanitizers being discharged into the pool This can result in bleaching or discoloration of areas around the pool inlet or in some cases bleaching or discoloration of the entire pool liner or paint C Excess trichlor in th...

Reviews: