![background image](http://html1.mh-extra.com/html/king-pigeon/s264/s264_user-manual_1969930018.webp)
Page 18 of 21 King Pigeon Hi-Tech. Co., Ltd. Ver 1.0
GSM/SMS/GPRS/3G/4G
Temperature&Humidity Data Logger
DOy:ON
Switch OFF(Open)
PWD +DOO+ channel number<nn>
DOx: OFF
DOy:OFF
Inquiry all DO Current
Status
PWD +DOE
DO1: ON/OFF
DO2:ON/OFF
Control
the
Pulse
Output
PWD+DOP+channel number<n>
(
Notice:
n=1,2. Cannot control together)
Set Pulse Output time
PWD +DOP+ channel number<nn> +T+xxxx
(
Notice:
xxxx=9999seconds, =0 stands for always
close)
DOx Pulse Output Time:xxxxS
Inquiry pulse output
time
PWD +DOT
Pulse Output Time:xxxS
13)
Setup the Temperature & Humidity Alarm Parameter
Command
Return SMS
Example
Setup
Temperature &
Humidity
Channel Name
PWD+AIN+Series
T+Channel
Name
AIN1:Temperature(Default)
AIN2:Humidity(Default)
1234AIN3TCooling Room
Inquiry the
Channel Name
PWD+AIN+Series
Number<nnn>
AIN1:Temperature(Default)
AIN2:Humidity(Default)
1234AIN12 to inquiry 1 and 2
Channel name, 1234AIN1 to
inquiry Channel 1 name.
Setup
Threshold
Value
PWD+AINR+Series
Lxxx+Hxxx#
(
Notice:
The xxx must be
3digits, e.g. -5C must use -05,
not -5. the xxx not supports
decimal point
)
If set Channel 1,then SMS
will be:
TEMP: Low: xxxC High: xxxC
If set Channel 2,then SMS
will be:
HUMI: Low: xxxC High: xxxC
1234AINR1L-05H023# to setup
low value as -5C, and high value
is 23C.
Inquiry
PWD+AINR
TEMP: Low:xxxC,High:xxxC;
HUMI:Low:xxxRH%,High:xxx
RH%;
1234AINR
Inquiry the
Current Value
PWD+AINE
TEMP: xxxx
C,Normal/High/Low;
HUMI:xxxRH%,High:xxxRH%;
The channel name refer to
setting
1234AINE
Setup the High
Alarm SMS
Content
PWD+AINH+Series
T+xxxxxx
(
Notice:
The H and T is fixed
Character,
Series
Number=Channel
Name,
xxxxx=SMS content, Max:40
Characters
)
AINHx: High Alarm (Default)
1234AINH1Thigh Alarm