background image

 

 

 

  Page 15 of 21              King Pigeon Hi-Tech. Co., Ltd.                Ver 1.0   

GSM/SMS/GPRS/3G/4G 

Temperature&Humidity  Data  Logger

 

8.SMS commands & APP (Recommend to use the APP)

 

Notice: 

1.

 

The default Password is 

1234

2.

 

The unit cannot support PIN Code Protected SIMCard. 

3.

 

You can program the GSM unit with SMS commands using your phone. 

4.

 

Remember that commands must be

 CAPITAL LETTERS

. It is PWD not pwd, CAP not Cap etc. Don't add 

spaces or any other character. 

5.

 

The 

pwd

 in the commands is means the password, when you use it, please in stand of it by the digital 

number; the capital letters 

PWD

 is the command letter, use PWD directly. 

6.

 

In some GSM operators they use different SMS parameter; the units can’t return the SMS confirmation in 
some gsm operators, but it can performance the functions correctly. Also, you can try to add the country 
code before the number, see the below settings: 

 

7.

 

If the password is correct but the command is incorrect, the S264/5/6 will return: 

SMS Format Error, 

Please check Caps Lock in Command!

 So please check the Command, or add the country code before 

the telephone number or check the input is in ENGLISH INPUT METHOD and CAPS LOCK. If password 
incorrect then will not any response SMS. 

8.

 

Once the GSM Unit received the SMS Command, will return SMS to confirmation, if no SMS return, please 
check your command or resend again. 

9.

 

The SMS commands that you will certainly use in the GSM units are the following: 

**SMS Commands For Program and Operation the S264/5/6**

 

1)

 

Setup the S264/5/6 SIMCard Number(Max 21 digits) 

This number is used for automatically adjust the time from GSM Operator. 

Command 

Return SMS 

Example 

PWD+TEL+SIMCard # 

Set success! 

1234TEL008613570810254# 

 

2)

 

Setup S264/5/6 system Time 

If you GSM Operator cannot provide the time source then must setup the system time after power on. 
Otherwise, the S264/5/6 will run it at mistake time. If you GSM Operator can provide time source, then no 
need to setup this time, but must setup the SIMCard number as 1) required.) 

Command 

Return SMS 

Example 

Setup 

PWD+DyymmddThhmm 

xx(Y)XX(M)XX(D)xx(H)X(M) 

1234D20170510T1258 

Inquiry 

PWD+D 

xx(Y)XX(M)XX(D)xx(H)X(M) 

1234D 

 

3)

 

Modify Password(4digits, Default is: 1234) 

Command 

Return SMS 

Example 

PWD

P

new password  [new password],This is the New Password, 

1234P4321 stands for change 

For example: 

E.g.: the country code is 

0086

, or 

+86

The user cell phone number is 

13600000000

 and has been assigned as a SMS Alert number, the simcard 

number in the panel is 

13512345678

.   

When you setup the number as the authorized number, please setup as 008613600000000 or 
+86136000000000. Not 13600000000.   

Summary of Contents for S264

Page 1: ...hold alarm with SMS text Message alert Interval Report Onsite temperature humidity to Your Mobile Phone by SMS S264 S265 S266 User Manual Ver 1 2 Date Issued 2017 09 15 King Pigeon Hi Tech Co Ltd www...

Page 2: ...y is 0 5 C Notice 1 Default version is GSM 2 For 3G WCDMA and 4G LTE version please tell our sales where you would like to use them This handbook has been designed as a guide to the installation and o...

Page 3: ...mory that can save 200000 events It provides 2 Relay outputs for automatically switch ON OFF devices when Temperature Humidity exceed high low value and remote switch ON OFF Device by SMS or GPRS 3G 4...

Page 4: ...bile phone directly In built rechargeable battery power lost recover alarm low maintenance 24 7 operation Internal 16MB memory logs more than 200000 records Support Android IOS APP easily friendly for...

Page 5: ...k flicks quickly registered successful will 2seconds flick once Alarm indicator while alarm occurrence will turn on Relay indicator any one relay close will turn on Armed indicator in Armed mode will...

Page 6: ...wires Interface Instruction DC in 9 36V DC9 36V positive input 1 5A for power on the Unit DC9 36V negative input 1 5A for power on the Unit Relay Output R1 Relay 1 output R2 Relay 2 output USB USB in...

Page 7: ...se refer to Chapter 8 Tips 1 Please insert the SIM Card firstly and install the GSM 3G 4G Antenna please power on to check the LEDs status according to above mentioned LED Definitions keep switch on i...

Page 8: ...In some computer it required download net framework 4 0 while installation then please click Yes to go to Microsoft website to download this service pack Step5 Choose the correct COM port then click...

Page 9: ...esh the com port Device ID 0 65535 non necessary This is mainly for monitoring center to identify the data logger if the application no needs to identify the data logger and then no need to fill in it...

Page 10: ...s in this line from Dial Relay ON OFF Dial Tick it stands for enable while alarm Dial to the authorized numbers Timer Report Tick it stands for enable to SMS report to this authorized numbers Arm Disa...

Page 11: ...arm SMS Content To setup the SMS Content when high alarm Low Alarm SMS Content To setup the SMS Content when low alarm Recovery SMS Content To setup the SMS Content when value back to normal from alar...

Page 12: ...Hour Minute Stands for what day and at what time does the Data Logger should execute the action Action Stands for what action does the Data Logger should to execute at the specified time E g as above...

Page 13: ...Point Name GPRS Access Point Name provided by GSM 3G Operator GPRS User Name GPRS User Name provided by GSM 3G Operator GPRS Password GPRS Password provided by GSM 3G Operator Upload Data Interval Tim...

Page 14: ...ce it full will automatically remove the earlier 100 records for new records The records will including all the values such as time T H value alarm so on Start to testing or work Step1 In order to sav...

Page 15: ...SMS 8 Once the GSM Unit received the SMS Command will return SMS to confirmation if no SMS return please check your command or resend again 9 The SMS commands that you will certainly use in the GSM un...

Page 16: ...SMS Content Setup PWD ACxxx Notice xxx stands for delay time range 000 999 minutes 000 stands for alarm immediately 999 stands for DC power lost will not alarm Default is 000 External DC Power Lost D...

Page 17: ...Notice xx 00 23 stands for hour yy 00 59 stands for minutes Default is 10 00 Daily SMS Report at xx xx Inquiry PWD DRT Daily SMS Report at xx xx Delete PWD DRTDEL 11 Setup Periodically SMS Report Inte...

Page 18: ...oom Inquiry the Channel Name PWD AIN Series Number nnn AIN1 Temperature Default AIN2 Humidity Default 1234AIN12 to inquiry 1 and 2 Channel name 1234AIN1 to inquiry Channel 1 name Setup Threshold Value...

Page 19: ...T is fixed Character Series Number Channel Name xxxxx SMS content Max 40 Characters AINTHRx Recovery Default 1234AINTHR1TRecovery Inquiry the Recovery SMS Content PWD AINTHR Series Number Notice The H...

Page 20: ...PASSWORD SMS Command Return SMS Content Set PWD AP apn username userpassword Notice apn access point name APN User Name Password Inquiry PWD AP Delete PWD APDEL 18 Wakeup GPRS Online SMS Command Retu...

Page 21: ...please refer to S264 5 6 GPRS 3G 4G Temperature Humidity Data Logger Protocol Instruction 10 Upgrade Firmware The S264 5 6 supports upgrade firmware via USB port directly If we upgraded the firmware f...