8.5 Personalized Parameter Setting
In order to improve the personalized use of this product, we specially add this setting.It can be
set according to different requirements of users.This setting includes the setting of battery
power bar setting, PAS level, current limit, PAS sensor, speed sensor, Throttle function and
system setting.There are seven items in total. See attached
Table 3
for detailed setting items.
8.5.1 Personalized password input
Press and hold the
UP
and
DOWN
keys for 2 seconds at the same time to enter the normal
setting state; then press and hold the
UP
and
DOWN
keys for 2 seconds at the same time to
enter the personalized parameter setting state.
The screen prompt "PSD. 3" indicates that you need to enter the permission password.Short
press the
MODE
key to shift and input the value through
UP
/
DOWN
.After the 4-digit
password is input, press the
MODE
key to confirm.If the password is correct, enter the
password setting interface, otherwise it will stay in the password input state.Press and hold
MODE
to exit.The password is 2962.
Select the content to be set by
UP
/
DOWN
, and press
MODE
to enter the corresponding
setting interface.