background image

electrIcAl InForMAtIon &

gettIng to know your MAcHIne

wArnIng!

ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE MACHINE DISCONNECTED FROM THE POWER SOURCE. 

FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!

kc-8500c information. 5 HP cyclone dust collector.

240V single phase operation.

The KC-8500C Cyclone Dust Collector comes with a 5 HP 34 Amp. 240V single phase motor. This Cyclone Dust Collector doesn’t come

with an electrical plug. Contact your local electrician to install appropriate plug or hardwire the machine to the electrical panel.

wArnIng:

YOUR CYCLONE DUST COLLECTOR MUST BE CONNECTED TO A 220V-240V, 1 PHASE ELECTRICAL SUPPLY. FAILURE

TO CONNECT IN THIS WAY CAN RESULT IN INJURY FROM SHOCK OR FIRE.

        

groundIng

Your Cyclone Dust Collector must be properly grounded. If it should malfunction or breakdown, grounding provides a path of least resistance

for electric current, to reduce the risk of electric shock. 

wArnIng:

IF NOT PROPERLY GROUNDED, THIS CYCLONE DUST COLLECTOR CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY

WHEN USED IN DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD IS WORN OR DAMAGED IN ANY WAY, HAVE

IT REPLACED IMMEDIATELY.

1. Locking caster

2. Drum

3. Drum plastic bag

4. Drum lid raising handle

5. Collector

6. Hose inlet- with caps (5 x 4” / 1 x 10”)

7. Impeller housing

8. Main motor

9. Canister auto-clean motor

10. Isolation panel

11. Vacuum pressure gauge

12. Magnetic switch & remote

13. Canister filter

14. Canister filter plastic bag

15. Drum vacuum pressure hose

MODEL                                                                                                                                                KC-8500C

Air suction capacity (Real/Nominal)                                                                                                     2701/4400 CFM

Noise level reading at 36”                                                                                                                    76 dB

Static pressure 

(inch of water)

                                                                                                                  14.5

Steel drum capacity                                                                                                                             54 gallon

Dust port opening                                                                                                                                                       5 x 4” / 1 x 10”

Motor                                                                                                                                                    5 HP, 34 Amp.

Voltage                                                                                                                                                 240V, 1 phase, 60 Hz

Assembled dimensions (LxWxH)                                                                                                         35” x 65-1/2” x 91-5/8”

Weight                                                                                                                                                  592 lbs

Summary of Contents for KC-8500C

Page 1: ...InstructIon MAnuAl COPYRIGHT 2019 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC 5 HP cyclone dust collector MODEL KC 8500C...

Page 2: ...tear negligence or accidents repairs done by an unauthorized service center alterations and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or fo...

Page 3: ...cIdentAl stArtIng Make sure the swich is in the OFF position before plugging in 17 use recoMMended AccessorIes Consult the manual for recommended accessories Follow the instructions that accompany the...

Page 4: ...r to keep airborne wood dust in heavy usage within acceptable limits you must regularly monitor airborne dust and maintain the cyclone dust collector to avoid exceeding dust limits Each application is...

Page 5: ...function or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock wArnIng IF NOT PROPERLY GROUNDED THIS CYCLONE DUST COLLECTOR CAN CAUSE ELE...

Page 6: ...shown using 6 flange head hex bolts 4 Install the drum lid supports F Fig 1 to the base B using 2 flange head hex bolts each support Notice the placement of the drum lid supports as shown in Fig 1 5...

Page 7: ...to clean motor small motor on top of the main impeller housing Follow assembly instruction further in this manual 8 The magnetic switch A Fig 5 hanging under the main impeller housing gets installed t...

Page 8: ...mall canister filter shaft tighten cap screws B Make sure one cap screw is tightened against the flat of the canister filter shaft 17 Next install the auto clean shaft C on canister filter shaft A tig...

Page 9: ...he intake housing B using 12 flange head hex bolts and flange head hex nuts 21 Position the collapsible hose C Fig 13 over the opening of the cyclone funnel and secure it in place using the hose clamp...

Page 10: ...n the drum Slide hose over fitting and secure hose with hose clamp B 28 Connect the other end of the drum pressure hose A Fig 17 to the fitting on the intake housing Slide hose over fitting and secure...

Page 11: ...the magnetic switch and to turn the machine on again first push the Emergency Twist OFF Stop button in then twist it clockwise until it pops out The magnetic switch ON button will only work once the...

Page 12: ...leaning becomes necessary it should be performed by an authorized service centre cAutIon WEARING A PARTICLE MASK RESPIRATOR FOR PROTECTION AGAINST FINE DUST PARTICLES DURING CLEANING IS HIGHLY RECOMME...

Reviews:

Related manuals for KC-8500C