King-Gage ES2 550*-1 Series Installation And Operation Instructions Manual Download Page 2

Page 2

ES2 Electronic Liquid Level Transmitter

EX-1832

© 2004 King Engineering Corporation. All rights reserved.

The information contained in this manual was accurate at
the time of release. Specifications are subject to change
without notice.

Warranty

 - All King Engineering products are guaranteed

to be free from defects in material and workmanship for
one year from the date of purchase. Any product or part
found to be defective under normal use within one year of
purchase will be repaired or replaced at no charge if
returned to the company at Ann Arbor, Michigan within
ten days of discovery of the defect. No other warranties,
whether expressed, implied or statutory, including the
warranties of fitness for a particular purpose or merchanta-
bility, are given by this agreement.
The exclusive remedy for nonconformity of these goods
shall be repair and/or replacement of the nonconforming
goods or parts.

Seller will not be liable for consequential damages resulting
from breach of this agreement. The term “consequential
damages” shall include but shall not be limited to damage
to all machines, equipment and goods other than the
goods sold hereby, interruption of production, loss of
profits, delays of any kind, administrative expense, and
overhead.

Revisions:

(A) August, 2004 - Original Release

Summary of Contents for ES2 550*-1 Series

Page 1: ...id Level Transmitter EX 1832 Effective August 2004 EX 1832 KING GAGE 4 20 mA Remote Liquid Level Transmitter ES2 Remote Liquid Level Transmitter Model 550 1 w Cable and Junction Enclosure Installation and Operation Instructions ...

Page 2: ...y at Ann Arbor Michigan within ten days of discovery of the defect No other warranties whether expressed implied or statutory including the warranties of fitness for a particular purpose or merchanta bility are given by this agreement The exclusive remedy for nonconformity of these goods shall be repair and or replacement of the nonconforming goods or parts Seller will not be liable for consequent...

Page 3: ...ro adjustments and signal loop connection terminals Range Designation A model number range designation is listed on the end of the transmitter housing The last two digits of the model number actually refer to the transmitter range As an example MODEL 5502 1 10 is a 0 10 psig range standard mount transmitter Model No Designations 55xx 1 xx Pressure Range 05 0 5 psig 10 0 10 psig 15 0 15 psig 30 0 3...

Page 4: ... 550 1 9 891 in 251 mm 8 875 in 225 mm MODEL 550 1 7 625 in 194 mm 2 250 in 57 mm Signal Junction Enclosure 4 33 in 110 mm YEL GRN WHT BLK RED 4 20 mA OUTPUT ZERO SPAN CAUTION METER KING GAGE Electronic 4 20 mA Sensor 2 96 in 75 mm Mounting holes 2 3 23 in 82 mm Model 5501 Short Mount Model 5503 Long Mount Model 5502 Standard Mount ...

Page 5: ... the supplied cable length will allow DO NOT SPLICE additional cable onto the transmitter Seal plugs caps are supplied with the Junction Enclo sure These are intended to be installed over the mounting hole provisions to seal the mounting hardware openings Note that mounting fasteners are not fur nished and must be supplied by customer Sensor Cable Rubber Ferrule Locking Nut Detail Mounting Junctio...

Page 6: ... Look for 10 to 12 twists per foot Use shielded cable with the shield connected to circuit common at one end only Never run signal carrying wires in the same conduit that carries power lines relay contact leads or other high level voltages or currents The signal output is transmitted through 4 20 mA current loops that are low impedance electric circuits Long cabling runscanincreasethesusceptibilit...

Page 7: ...e previous page that permit accurate reading without disturbing the signal loop wiring Important Set meter for DC current mA or 001 Amp scale Internal resistance through the meter must be 20 ohms or less Higher resistance values will erroneously show lower milliamp reading on meter Note Always re install cover when done Sensor Cable The transmitter cable contains five 5 individual wires that are t...

Page 8: ...ned 16 x Tank Pressure 4 mA Output NOMINAL psig RANGE MODEL RANGE 5701 1 15 PSIG Sensor Assembly B A Tank Milk 1 032 sp gr Example mA Output Calculation for Tank Gauging Application The following example shows how the milliamp output of the sensor at full tank can be calculated The Reserve represents the distance from the lowest point on the bottomofthetanktotheinstalledsensor Full isthelevel of c...