GETTING TO KNOW YOUR GENERATOR

MODEL

KCG-6500GE

Peak Wattage (starting)
Running Wattage 
AC Outputs
DC Output
Engine (OHV)
No load speed
Displacement (cc)
Fuel
Fuel tank (L)
Oil capacity (L)
Run time
Noise level
Dimensions (LxWxH)
Weight

6500W
5500W
3(2x 120V/45.8A)(1x 240V/22.9A)
12V (8.3A)
13 HP
3,600 RPM
389
Unleaded Gasoline
25
1
6-7 hrs.
73 dB(A)
27” x 19” x 22”
187 lbs.

1. Fuel level indicator window with float gauge.
2. Fuel cap. 

Make sure the fuel cap is always screwed on tightly.

3. Fuel tank. 

Unleaded gasoline only! 25 Liter capacity. 

4. Muffler.

Warning! Muffler gets hot. Avoid placing any flammable

materials near the exhaust outlet during operation.

5. AC Breaker.

The AC breaker turns off automatically when the load

exceeds the generator rated output. Reduce the load to within
specified generator rated output if AC breaker turns off.

6. DC Fuse.
7. DC Terminals. 

Mainly used for charging car batteries.

8. AC 120V/240V Twist lock outlet. 

This twist lock outlet allows 120V

or 240V operation, see instructions further in this manual.

9. Battery. 

This battery supplies power to the electric start.

10. Low oil warning indicator light. 

This generator detects and

shuts off automatically when the oil level is too low. In case of an
auto shut-off and the indicator light is ON, check oil level with dipstick
(#18) and fill to recommended level with SAE 10W30 engine oil.

11. Grounding terminal. 

This generator must be grounded, see

grounding instructions.

12. Reset button. 

Resets the 120V receptacle after an overload.

13. Voltmeter. 

Indicates the voltage rating.

14. Duplex AC 120V outlets. 

Plug up to 2-120V appliances or a power

bar, make sure the amps requirement does not exceed the amps
rating or else the AC breaker will automatically shut-off the power
output.

15. Power indicator light. 

The power indicator light comes on when

the switch has been turned on and the motor has been started
using the key start or the recoil starter.

16. Electric Start Power ON Key Switch. 

To turn engine on, first turn

key to ON, make sure low oil warning light does not come on, turn
key further and hold until engine starts and release. Move switch to
Off position to stop generator.

17. Recoil starter. 

Alternative starter

,

starts the engine manually, key

switch must in the “ON” position.

18. Oil gauge dipstick. 

Check the oil level using this oil gauge dipstick.

19. Spark plug/cover. 

The spark plug must be check periodically for

carbon deposits and/or discoloration, see maintenance section.

20. Fuel Shut-off Valve. 

Regulates the flow of fuel to the engine. The

fuel shut-off valve must be fully opened before starting the engine.

21. Carburetor throttle (choke). 

Once the engine is started, it is

necessary to gradually pull the carburetor throttle hook to the “ON”
position, see instructions futher in this manual.

22. Air cleaner filter/cover. 

Periodically the air cleaner filter must be

checked and maintained, see maintenance section.

Summary of Contents for KCG-6500GE

Page 1: ...RT INSTRUCTION MANUAL COPYRIGHT 2007 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL KCG 6500GE Read this manual Do not attempt to operate this generator until you have read and understood the safe...

Page 2: ...ability caused by shipping improper handling improper installation improper maintenance improper modification or the use of accessories and or attachments not specifically recommended Repairs necessar...

Page 3: ...ock will occur Be sure to ground earth the generator ELECTRICAL CONNECTION NOTES Avoid connecting the generator to commercial power outlet Avoid connecting the generator in parallel with any other gen...

Page 4: ...bient such as storage rooms or garages can interfere with its proper ventilation features causing overheating and possible ignition of the materials or buildings Operate generator in a clean dry well...

Page 5: ...ine oil 11 Grounding terminal This generator must be grounded see grounding instructions 12 Reset button Resets the 120V receptacle after an overload 13 Voltmeter Indicates the voltage rating 14 Duple...

Page 6: ...EL WARNING This generator has been shipped from the factory without or with very little oil in the crankcase Operating the unit without oil can damage the engine Always check the oil level before star...

Page 7: ...ds the engine to the ON position on warm engine starts 4 Insert starter key A Fig 6 into ignition B turn key to ON position Make sure the low oil warning light does not come on Turn and hold the key u...

Page 8: ...sensitive appliances such at TV s VCR s microwaves ovens computers and cordless telephones into a UL CSA listed voltage surge protector then connect the UL CSA listed voltage surge protector to the ge...

Page 9: ...age generator 2500 maximum starting wattage Wattage Requirement Chart below This is only a guideline each appliance or electrical device needs to be checked for its specific operating load DETERMINING...

Page 10: ...between 0 7 0 8mm If the clearance exceeds 0 8mm replace the spark plug 4 Reinstall spark plug in the reverse order Fuel Filter Maintenance 1 Set the fuel shut off valve A Fig 12 to the OFF position a...

Page 11: ...ntilation 1 Faulty rectifier 2 Faulty windings in field coil 3 Faulty wire harness CORRECTION 1 Add fuel or oil 2 Turn to ON position 3 Replace spark plug 4 Adjust choke accordingly 5 Open fuel shut o...