King Canada KCG-1501GN Instruction Manual Download Page 5

1. Fuel cap. 

Make sure the fuel cap is always screwed on tightly.

2. Fuel tank. 

Unleaded gasoline only! 7 Liter capacity. 

3. DC Reset. 

Resets the corresponding 12V DC outlet.

4. AC circuit breaker. 

The AC breaker turns off automatically when the

load exceeds the generator rated output. Reduce the load to within

specified generator rated output if AC breaker turns off.

5. Grounding terminal. 

This generator must be grounded, see ground-

ing instructions.

6. Duplex AC 120V outlets. 

Plug up to 2-120V appliances or a power

bar, make sure the amps requirement does not exceed max amps or

else the AC breaker will automatically shut-off the power output. 

7. DC

terminals. 

For use with 12V appliances.

8. Low oil warning indicator light. 

This generator detects and shuts

off automatically when the oil level is too low. In case of an auto shut-

off and the indicator light is ON, check oil level with dipstick (#8) and

fill to recommended level with SAE 10W30 engine oil.

9. Power ON switch. 

This switch must be switched to “ON” before

pulling recoil starter.

10. Air cleaner element/cover. 

Periodically the air cleaner filter must

be checked and maintained, see maintenance section.

11. Carburetor throttle lever (choke). 

Once the engine is started, it is

necessary to gradually move the carburetor throttle lever to the

“OPEN” position, see instructions futher in this manual.

12. Fuel level gauge. 

Indicates the fuel level in the tank.

13. Oil gauge dipstick. 

Check the oil level using this oil gauge dipstick.

14. Fuel Shut-off Valve. 

Regulates the flow of fuel to the engine. The

fuel shut-off valve must be fully opened before starting the engine.

15. Recoil starter. 

Starts the engine.

MODEL                                                                                                          KCG-1501GN

Peak Wattage (starting)

Running Wattage 

AC current (120V)

Engine (OHV)

No load speed

Displacement (cc)

Fuel

Fuel tank (L)

Oil capacity (L)

Run time (half load)

Noise level

Dimensions (LxWxH)

Weight

1500W

1400W

11.6 Amp

3 HP

3,600 RPM

98

Unleaded Gasoline

7

0.5

9 hrs.

66 dB(A)

18-1/2” x 14” x 15-3/4”

56 lbs

GETTING TO KNOW YOUR GENERATOR

Summary of Contents for KCG-1501GN

Page 1: ...TION MANUAL COPYRIGHT 2016 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL KCG 1501GN Read this manual Do not attempt to operate this generator until you have read and understood the safety operati...

Page 2: ...NOT TRANSFERABLE AND DOES NOT COVER Damage or liability caused by shipping improper handling improper installation improper maintenance improper modification or the use of accessories and or attachmen...

Page 3: ...will occur Be sure to ground earth the generator ELECTRICAL CONNECTION NOTES Avoid connecting the generator to commercial power outlet Avoid connecting the generator in parallel with any other generat...

Page 4: ...ent such as storage rooms or garages can interfere with its proper ventilation fea tures causing overheating and possible ignition of the materials or build ings Operate generator in a clean dry well...

Page 5: ...nd fill to recommended level with SAE 10W30 engine oil 9 Power ON switch This switch must be switched to ON before pulling recoil starter 10 Air cleaner element cover Periodically the air cleaner filt...

Page 6: ...tion the oil gauge dipstick and tighten it by turning it clockwise FUEL LEVEL WARNING Make sure there is enough fuel in the fuel tank before operating 1 If filling tank for the first time or any other...

Page 7: ...y gas Make sure all electrical appliances are unplugged before attempting to start genera tor To safely start your generator follow the steps 1 through 8 in Fig 5 below STARTING STOPPING PROCEDURES Fi...

Page 8: ...TV s VCR s microwaves ovens computers and cordless telephones into a UL CSA listed voltage surge protector then connect the UL CSA listed voltage surge protector to the generator Overloading the gener...

Page 9: ...starting wattage Wattage Requirement Chart below This is only a guideline each ap pliance or electrical device needs to be checked for its specific operat ing load DETERMINING WATTAGE REQUIREMENTS Not...

Page 10: ...reverse order Fuel Filter Maintenance In order to clean the fuel filter inside the fuel cock it is necessary to drain all gasoline from the tank and the carburetor see section Generator Storage below...

Page 11: ...1 Generator overloaded 2 Insufficient ventilation 1 Electrical short in connected item 2 Overloaded CORRECTION 1 Add fuel or oil 2 Turn to ON position 3 Replace spark plug 4 Adjust choke accordingly 5...

Reviews: