King Canada KCG-1501GN Instruction Manual Download Page 3

BE CAREFUL!

DO NOT USE 

IN YOUR HOUSE

DO NOT CONNECT TO 

HOUSEHOLD CIRCUIT

DO NOT USE IN 

WET CONDITIONS

KEEP FLAMMABLE 

MATERIALS AWAY

STOP ENGINE!

NO SMOKING!

DO NOT SPILL GASOLINE!

BASIC SAFETY INFORMATION

EXHAUST FUMES ARE DANGEROUS

•Never operate the engine in a closed area or it may cause uncon-

sciousness and death within a short time. Operate in a well ventilated

area.

FUEL IS HIGHLY FLAMMABLE AND POISONOUS

•Always turn off the engine when refueling.

•Never refuel while smoking or in the vicinity of an open flame.

•When operating or transporting this generator, be sure to keep it up-

right. If it tilts, fuel may leak from the carburetor or fuel tank.

ENGINE AND MUFFLER MAY BE HOT

•Place the generator in an appropriate location, away from children

and pedestrians.

•Avoid placing any flammable materials near the exhaust outlet during

operation.

•Keep a 4ft. clearance from buildings or other equipment around the

generator to prevent overheating.

ELECTRIC SHOCK PREVENTION

•Never operate in rain or snow.

•Never touch the generator with wet hands or electric shock will occur.

•Be sure to ground (earth) the generator.

ELECTRICAL CONNECTION NOTES

•Avoid connecting the generator to commercial power outlet.

•Avoid connecting the generator in parallel with any other generator.

WARNING!

The engine muffler will be very hot after use, avoid touch-

ing the engine or muffler while they are still hot.

FUEL

Make sure there is sufficient fuel in the tank.

GROUNDING

Make sure to ground (earth) the generator.

SPECIFIC SAFTEY INFORMATION

Attempting to connect generator directly to the electrical system

of any building structure.

Back feeding electricity through a building’s electrical system to the

outside utility feed lines could endanger repair persons attempting to

restore service.

Failure to use a double throw transfer switch when connecting to a

structure's electrical system can damage appliances and 

WILL VOID

the manufacturer's warranty.

Never backfeed electricity through a structure's electrical system. To

connect to a structure's electrical system in a safe manner, always

have a Double-Throw Transfer Switch installed by a qualified electri-

cian and in compliance with local ordinances. (When installing a Dou-

ble-Throw Transfer Switch, a minimum of 10 gauge wiring must be

used).

BASIC

&

SPECIFIC

SAFETY PRECAUTIONS

WHEN 

REFUELING;

Summary of Contents for KCG-1501GN

Page 1: ...TION MANUAL COPYRIGHT 2016 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC MODEL KCG 1501GN Read this manual Do not attempt to operate this generator until you have read and understood the safety operati...

Page 2: ...NOT TRANSFERABLE AND DOES NOT COVER Damage or liability caused by shipping improper handling improper installation improper maintenance improper modification or the use of accessories and or attachmen...

Page 3: ...will occur Be sure to ground earth the generator ELECTRICAL CONNECTION NOTES Avoid connecting the generator to commercial power outlet Avoid connecting the generator in parallel with any other generat...

Page 4: ...ent such as storage rooms or garages can interfere with its proper ventilation fea tures causing overheating and possible ignition of the materials or build ings Operate generator in a clean dry well...

Page 5: ...nd fill to recommended level with SAE 10W30 engine oil 9 Power ON switch This switch must be switched to ON before pulling recoil starter 10 Air cleaner element cover Periodically the air cleaner filt...

Page 6: ...tion the oil gauge dipstick and tighten it by turning it clockwise FUEL LEVEL WARNING Make sure there is enough fuel in the fuel tank before operating 1 If filling tank for the first time or any other...

Page 7: ...y gas Make sure all electrical appliances are unplugged before attempting to start genera tor To safely start your generator follow the steps 1 through 8 in Fig 5 below STARTING STOPPING PROCEDURES Fi...

Page 8: ...TV s VCR s microwaves ovens computers and cordless telephones into a UL CSA listed voltage surge protector then connect the UL CSA listed voltage surge protector to the generator Overloading the gener...

Page 9: ...starting wattage Wattage Requirement Chart below This is only a guideline each ap pliance or electrical device needs to be checked for its specific operat ing load DETERMINING WATTAGE REQUIREMENTS Not...

Page 10: ...reverse order Fuel Filter Maintenance In order to clean the fuel filter inside the fuel cock it is necessary to drain all gasoline from the tank and the carburetor see section Generator Storage below...

Page 11: ...1 Generator overloaded 2 Insufficient ventilation 1 Electrical short in connected item 2 Overloaded CORRECTION 1 Add fuel or oil 2 Turn to ON position 3 Replace spark plug 4 Adjust choke accordingly 5...