MAINTENANCE & STORAGE
MAINTENANCE
Before doing any maintenance or adjustments to your air compressor,
the following safety precautions should be taken:
- Disconnect electrical power.
- Drain air tank of pressure.
Daily or before each use
1. Check oil level. Oil level should be centered with the red dot.
2. Drain condensation from tank.
3. Check for any unusual noise or vibration.
4. Be sure all nuts and bolts are tight.
Monthly
1. Inspect air system for leaks by applying soapy water to all joints.
Tighten those joints if leakage is observed.
250 hours or six months (whichever comes first)
1. Change compressor oil. See following instructions.
2. Replace oil more often if compressor is used near paint spraying
operations or in dusty environments.
CHANGING OIL
To change oil, oil must be drained from the crankcase by removing oil
sight glass (C) Fig.7. Drain oil and replace oil sight glass. To fill the
crank case with oil (approx. 450ml), first unscrew and remove oil
breather cap (A), pour air compressor oil (SAE 30 weight non-detergent
oil) into crankcase oil opening (B) until the oil level reaches the center
red dot on the oil sight glass (C). Retighten oil breather cap (A).
KEEP TOOL CLEAN
Periodically blow out all air passages with dry compressed air. Clean all
plastic parts with a soft damp cloth. NEVER use solvents to clean
plastic parts. They could possibly dissolve or otherwise damage the
material.
CAUTION
: Wear safety glasses while using compressed air.
FAILURE TO START
Should your compressor fail to start, check to make sure the prongs on
the cord plug are making good contact in the outlet. Also, check for
blown fuses or open circuit breakers in the line. If using an extension
cord, try using a longer air hose instead and try to start compressor
again.
STORAGE
1. Set the “OFF/AUTO” button to “OFF”.
2. Lift and turn the regulator counterclockwise to set the outlet pressure
to zero.
3. Remove the air tool or accessory .
4. Pull ring on safety valve (H) Fig. 5, allowing air to bleed from the
tank, until tank pressure is approximately 20psi. Release safety
valve ring.
5. Drain water from air tank. Turn drain valve (B) Fig. 4, counterclock-
wise, to open.
NOTE: If drain valve is plugged, pull ring on safety valve (H) Fig. 5, and
hold until air pressure has been released. The valve can then be
removed, cleaned, and reinstalled.
6. After the water has been completely drained, turn drain valve to
close. The air compressor can now be stored.
7. Protect the electrical cord and air hose from damage by winding
them loosely around the air compressor.
8. Store the air compressor in a clean and dry location.
FIGURE 7
TROUBLE
No start condition
Low pressure
Safety valve releasing
Oil discharge in air
POSSIBLE CAUSE
Fuse blown or circuit breaker tripped
Loose electrical connections
Overheated motor
Air leak in safety valve
Restricted air filter
Defective check valve
Defective pressure switch or improper
adjustment
Improper oil viscosity
Too much oil in crankcase
Compressor overheated
Restricted air filter
CORRECTIVE ACTION
Check voltage or eliminate extension cord or reset
Check wiring connections
Press the reset button or wait for automatic reset
Check valve manually by pulling upwards on ring. If condition
persists replace valve
Clean or replace as necessary
Replace check valve
Check for proper adjustment and if problem persists, replace
pressure switch
Replace oil with SAE 30 oil
Drain crankcase and fill to proper level
Air pressure regulated too high
Replace filter
TROUBLE SHOOTING