Kinetic Solar K-Rack™
Installation guide
Page 15 of 37
27 May 2019
6.4.
Joiners
If there are any rail joiners, adequate bonding must be used between rail sections. If an
anodized rail is being used then a KJS2W joiner must be used.
Figure 14 Joiner Compatibility
6.5.
Thermal Break
If there is a thermal break, two ground lugs (KHGLUG-M, KHGLUG-A or KHGLUG-G)
either side of the break, joined with a piece wire that meets the specifications in the
table below is required.
6.6.
Grounding
Grounding is to be achieved through the Kinetic Grounding Lug (KHGLUG-M,
KHGLUG-A or KHGLUG-G) and a copper or aluminum wire that meets the
specifications in the table below. Systems mounted in a conventional rail design require
a minimum of one ground lug per row. Systems mounted in a shared rail design require
a minimum of one ground lug per array.