1.
Control MCB
– switches the control transformer and electronics. If the unit is linked to
others then turning this off may not turn off the electronics as these can be phantom
powered by other units. Disconnect the data/control in and thru connectors as well to
ensure that the unit is off.
2.
Drive MCB
– switches power to the drive and brake supply voltage to the hoist. The
hoist is safe and cannot be moved if this circuit breaker is off.
3.
Menu Display
– displays all the information about the unit status and position as well
as allowing viewing and alteration of menu parameters.
4.
Menu Button
– accesses the menu system and navigates backwards through the
menu tree once within it. When pressed in conjunction with enter it alternates the unit
in and out of manual mode.
5.
Enter Button
– confirms selections within the menu system. When pressed in
conjunction with menu it alternates the unit in and out of manual mode.
6.
Menu Up Button
– moves up the current menu items, increments the currently
displayed parameter value or when used in conjunction with the down button allows
the ultimate limit to be bypassed.
7.
Menu Down Button
– moves down the current menu items, decrements the currently
displayed parameter value or when used in conjunction with the up button allows the
ultimate limit to be bypassed.
8.
Manual Up Button
– enables the hoist to be run upwards locally without the use of an
external controller.
9.
Manual Down Button
– enables the hoist to be run downwards locally without the
use of an external controller.
10.
Manual Speed Control
– set the speed of all local manual moves.