OPERATION
Caution:
Prior to plugging in the unit into your power outlet ensure the ON/OFF switch (3) is in
the off position.
1. To turn the ventilator ON push the ON/OFF switch across as shown in (fig 1.)
2. To Turn the ventilation fan OFF push the ON/OFF switch (3) as shown in (fig 2.)
For Exhausting Contaminated Air:
If the ventilation fan will be used to exhaust contaminated air from a situation such as welding, the fumes
collected should be ducted to the outside of your work area or building. The ventilation fan must be
located as close as possible to both the operation and the outside of the building.
Note:
A ventilation duct may be required for this type of application, fitting a ventilation duct will reduce
the airflow by about 5-15 CFM for every additional meter of hose or installed ducting (not included),
however KP1004 Ventilation duct can be purchased as an optional accessory.
Note:
Each 90° change in air flow direction (as with an elbow) will reduce the airflow approximately
15-20 CFM.
KP1004 Ventilation Ducting (optional accessory not supplied)
The KP1004 ventilation ducting (5m) is designed to be attached to a 300mm portable ventilation fan
when required.
Contact your local Kincrome dealer or visit our website at www.kincrome.com.au for more information
300
MM
PORTABLE VENTILATION
FAN
Warranty given by Kincrome Australia Pty Ltd of 3 Lakeview Drive, Caribbean Park, Scoresby, Victoria (Tel 1300 657 528). The applicable warranty
period (12 months) commences on the date that the product is purchased. If this product has materials or workmanship defects (other than
defects caused by abnormal or non warranted use) you can, at your cost, send the product to place of purchase, an authorised Kincrome service
agent or one of Kincromes addresses for repair or replacement. Your rights under this warranty are in addition to any other rights you have
under the Australian Consumer Law or other applicable laws. Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or
damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount
to a major failure. For further details please visit www.kincrome.com.au or call us. Due to minor changes in design or manufacture, the product
you purchase may sometimes differ from the one shown on the packaging.
(Fig 1)
(Fig 2)
KP1004 Ducting
Not included
ON
OFF
For Supplying Fresh Air:
WARNING!:
It is the responsibility of the operator/user to ensure that sufficient ventilation (airflow) will be supplied to the
working environment and the air supply duct will be positioned in accordance with all applicable safety codes governing the
use of a blower to supply fresh air to a confined area. IN NO CASE SHOULD THE BLOWER BE INSTALLED OR PLACED INSIDE
THE CONFINED AREA THAT IS TO BE VENTILATED.
The ventilation fan can also be used to blow fresh air into a confined work space such as a tank or man hole.
CARE & MAINTENANCE
Caution: Prior to making any adjustments, cleaning or movements of the ventilator ensure the ventilator is turned OFF, the
blades are stationary and the ventilator unplugged from mains power.
1. Disconnect the unit from the wall socket prior to cleaning the unit.
2. Clean the fan only with a slightly damp, soapy cloth, but ensure it is not too wet.
After wiping down the unit with the soapy cloth, dry any wet spots with a dry paper towel or dry clean cloth.
3. Do Not spray or rinse the ventilator with any form of liquid and/or detergents.
4. Store the fan in a clean dry area when not in use.