5

INDUSTRIAL HAMMER CHISEL KIT 8 PCE

9) Operation

Note: The air hammer chisel should not be operated without loading.

1. 

Screw in Nitto Style Fitting (7) to the air inlet (1). Thread (teflon) tape may be required to ensure a leak free seal

2. 

Connect the air hose to the air inlet (1) of the tool.

3. 

With the proper chisel attached to the Air Hammer, attach the air supply to the Air Inlet (1) at the base on the handle.

4. 

Turn on the air supply.

5. 

Press the chisel against the work surface and squeeze the Trigger (3) to start the tool. Do not force the Air Hammer against 

 the work surface. 

6. 

If the tool requires more force to accomplish the task, verify that the tool receives sufficient, unobstructed airflow (FAD) and 

increase the pressure (PSI) output of the regulator up to the maximum air pressure rating of this tool.

Caution: Do not exceed tool’s maximum air pressure rating (90 PSI). If tool still does not have sufficient force at maximum pressure  
                  and sufficient airflow, then a larger tool may be required. sufficient airflow, then a larger tool may be required. 

7. 

To prevent accidents, turn off the tool, detach the air supply, safely discharge any residual air pressure in the tool, and release 

the trigger after use. Clean external surfaces of the tool with clean, dry cloth, and apply a thin coat of tool oil.

Caution: Never point a loaded hammer chisel at anyone at any time. For safety concerns, if a chisel is loaded please do not point it  

                   at any part of the body.

10) Cleaning, Maintenance, and Lubrication

Note: 

These procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the  

air-operated tool.
The air motor and bearing uses compressed air to power the tool. Moisture in compressed air will rust the motor components, you 

must lubricate the motor daily.

Lubrication

1. 

Disconnect the tool from the air supply holding it so the air inlet (1) faces up.

2. 

Hold the trigger (3) down and put 4 to 5 drops of Kincrome air tool oil in the air inlet. Holding the trigger down helps circulate oil 

in the motor. 

3. 

Connect the tool to air supply, cover the exhaust (2) with a towel and run for a few seconds.  

 

WARNING! 

Any excess oil in the motor is immediately expelled from the exhaust (2) .Always direct exhaust (2) away 

 from people or objects. 

Storage

1. 

Avoid storing the tool in a location subject to high humidity. If the tool is left as it is used, the residual moisture inside the tool 

can cause rust. Before storing and after operation, oil the tool and run it for a short time.

2. 

Regular inspection should be carried out of the spring, quick change chuck and chisels irrespect of wear.

11) Warranty

Warranty given by Kincrome Australia Pty Ltd of 3 Lakeview Drive, Caribbean Park, Scoresby, Victoria (Tel 1300 657 528). 
The applicable warranty period (24 months) commences on the date that the product is purchased. If this product has materials or 
workmanship defects (other than defects caused by abnormal or non warranted use) you can, at your cost, send the product to place 
of purchase, an authorised Kincrome service agent or one of Kincromes addresses for repair or replacement. Your rights under this 
warranty are in addition to any other rights you have under the Australian Consumer Law or other applicable laws. Our goods come 
with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major 
failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or 
replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. For further details please visit 
www.kincrome.com.au or call us. Due to minor changes in design or manufacture, the product you purchase may sometimes differ 
from the one shown on the packaging.
IMPORTANT! If the tool fails to operate correctly,  call customer service on 1800 657 528 for advice on the best resolution for your 
situation. If a resolution cannot be achieved over the phone please take the tool and all related accessories to an authorised service 
centre or place of purchase showing proof of purchase for assistance.

Summary of Contents for K13255

Page 1: ...INDUSTRIAL HAMMER CHISEL KIT 8 PCE INDUSTRIAL HAMMER CHISEL KIT 8 PIECE K13255 ED1 December 15 3000 BLOWS PER MINUTE SPEED TRIGGER QUICK MAX 1492NM TORQUE 2 YEAR WARRANTY VARIABLE CHANGE CHUCK...

Page 2: ...w your product 1 Air Inlet 2 Exhaust 3 Variable Trigger 4 Retaining Spring 5 Quick Change Chuck 6 5 Peice Chisel Set 7 Nitto Style Fitting Model No K13255 Description Industrial Hammer Chisel Kit 8 Pc...

Page 3: ...g and balance at all times Proper footing and balance enables better control of the tool in unexpected situations g Use safety equipment A dust mask non skid safety shoes and a hard hat must be used f...

Page 4: ...people who have impaired blood circulation to the hand past hand injuries nervous system disorders diabetes or Raynaud s Disease should not use this tool If you feel any symptoms related to vibration...

Page 5: ...quick coupler be fitted for optimal operation as shown on Figure A 2 An in line shut off ball valve is an important safety device it shut off the air supply even if the air hose is ruptured The shut o...

Page 6: ...nlet Holding the trigger down helps circulate oil in the motor 3 Connect the tool to air supply cover the exhaust 2 with a towel and run for a few seconds WARNING Any excess oil in the motor is immedi...

Page 7: ...s No Description Q ty 01 K13255 1 Trigger Assembly Kit 1 02 K13255 2 Chisel Retaining Spring 1 03 K13255 3 Quick Change Chuck 1 04 K13255 4 4 Pack of Chisels 1 Kincrome reserve the right to change spa...

Page 8: ...www kincrome com au...

Reviews: