Kimo VT 200 User Manual Download Page 1

Anemometer

VT 200 

Supplied

with

Calibration

 

certificate

Summary of Contents for VT 200

Page 1: ...Anemometer VT 200 Supplied with Calibration certificate ...

Page 2: ......

Page 3: ...Area 8 Duct type 8 Sizes 8 K2 factor 8 Units 9 Using Hotwire 9 Air velocity menu 9 Hold Min Max 9 Average 9 Point point average 9 Automatic average 9 Automatic point point average 9 Configuration 10 Thermocouple type 10 Display 10 Units 10 Recording 10 Parameters 12 Language 12 Date hour 12 Beep 12 Extinction 12 Contrast 12 Backlit 12 Key locking 12 Code 12 Downloading data 12 V General Informatio...

Page 4: ...0 to 80 C 0 3 of reading 0 25 C 0 1 C C F From 0 to 99 999 m3 h 3 of reading 0 03 area cm2 1 m3 h m3 h cfm l s m3 s m s fpm Km h Air velocity Temperature Airflow From 20 to 80 C 0 4 of reading 0 3 C 0 1 C C F From 0 to 99 999 m3 h 3 of reading 0 03 area cm2 1 m3 h m s fpm Km h Air velocity Temperature Airflow From 20 to 80 C 0 4 of reading 0 3 C 0 1 C C F From 0 to 99 999 m3 h 3 of reading 0 03 ar...

Page 5: ...r protection Top view Module connections mini Din C1 connector mini Din C2 connector Graphic display Hour Value Unit Circular menu Memory status used Battery level Keypad On Off key Access keys for circular meny Escape key Browsing joystick 4 directions Validation II Introduction ...

Page 6: ...s system Wire probes with Smart plus system are automatically recognized when connected to the instrument mini Din C1 connector mini Din C2 connector Probes are connected on min DIN connectors C1 and or C2 Wireless probe instrument communication Wireless communication between probe and instrument with automatic recognition after power up Secured Mini Din Connector Connections II Introduction Non e...

Page 7: ...asure Params Select a sub menu with access keys Measurement Communication interrupted Check probes connection Select a sub menu with access keys or with arrow keys 7 III Browsing Airflow measurement display Select sub menu with arrows keys or access keys Return to previous screen Air velocity measurement display Rec Hold Area Avg Params Veloci Config Rec Probe Config Airflow Params Avg Infos Probe...

Page 8: ...w probe information plugged to C2 Module C1 or wireless connections See Connections p 6 for more information about connections Available information are Sensor type Serial number Date of last calibration or adjustement Probes Status enabled ou disabled On enabled mode the probe is connected the measurement is carried out and the value is displayed On disabled mode the probe is connected the measur...

Page 9: ...Average This function allows to calculate the average value of various points that you can select Numbers of selected points and parameter for which calculation is carried out are displayed For adding a new measuring point to this calculation press OK to confirm If you click on average icon max and min values standard deviation average of each parameter and numbers of measuring points will be disp...

Page 10: ...to with and Confirm wih OK c Select Name with and Confirm wih OK or Enter dataset name with the arrow keys and e Confirm wih OK d Enter dataset time and interval of time between 2 measurements by selecting Period with access key Select Duration or Interval with and Confirm wih OK Enter minutes and seconds with arrow keys and from 1 minute to 24 hours for the duration and from 5 seconds to 10 minut...

Page 11: ...Preview of tables of points of datasets a Go to Recording menu b Select Display Click on OK to validate c Select dataset name with arrow keys et Click on OK to validate Summary screen of selected dataset is displayed From this screen you can Select other dataset using arrow keys t and u Display data of other channels using arrow keys p and q d Click on Mesure to display values table of selected da...

Page 12: ... Select language with arrow keys and and Confirm wih OK Language RF logging This sub function allows to enable or disable the RF Logging Click on OK or to enter into the sub function Select respectively ON or OFF with and in order to enable or disable this function Confirm wih OK This sub function allows to modify the backlit Click on OK or to enter Select your backlit level from 0 to 9 or AUTO wi...

Page 13: ...e 1 year guarantee for any manufacturing defect return to our After Sales Service required for appraisal Maintenance Warranty Info menu This menu allows to view the serial number of instrument and firmware version Battery When battery indicator flashes it is recommended to change the batteries 1 Remove the front part at the back of the instrument 2 Remove batteries 3 Insert new batteries AA LR6 1 ...

Page 14: ......

Page 15: ......

Page 16: ...tractual document We reserve the right to modify the characteristics of our products without prior notice Once returned to KIMO required waste collection will be assured in the respect of the environment in accordance to 2002 96 CE guidelines relating to WEEE ...