Installation steps continuation….

5. Fasten and secure mounting base plate onto the single-gang electrical box in the wall with 

two (2) fasteners

    No. 6-32 machine screws.

Electrical Box

Mounting Base Plate

No. 6-32 Machine Screw

Electrical Box

**Note:  Sequence of mirror mounting parts with components per UL standard 1598**

6. Replace mirror base over mounting base plate and secure using the three (3) mounting Hex screws.
    Restore power to the site and turn mirror fixture on at power switch on base.

Power Supply Electrical Data 

Voltage rating:

Input: AC120V, 50-60Hz

Output: DC 15V

Wattage rating:

12 W

Electric current rating:

0.1 A