Aptations, Inc. recommends using a qualified electrician for all electrical wiring procedures and installation.
Turn off all electrical power to the installation site.
MIRROR IS NOT DESIGNED FOR IN-SHOWER USE.
A standard 120V~ AC single-gang electrical box (size
4 H x 2-1/8 W x 1-7/8 to 2-1/16 D inches)
must be installed at
the desired location of the wall before continuing. Location must be dry and accessible for service. Location must be
hardwired to a grounded branch circuit. Installation must include ground wire.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED
Installation steps (refer to the pictures, subject to the product)
1. Remove the mounting screws on both sides and top of the mirror's base.
2. Detach mounting base plate from the base carefully to ensure electrical connections are not pulled during removal.
3. At wall install site, feed grounded branch electrical wires through pre-installed single-gang electrical box
and reserve convenient length. Connect electrical wires to fixture's power supply box leads.
4. Internal power supply box connects to a grounded branch circuit using INPUT wire leads
LIVE and NEUTRAL.
From mirror base plate, connect GROUND wire lead to same branch circuit.
Stow electrical connections in single-gang electrical box.
*Note: While wiring, do not let mirror fixture hang from connected wires.
Doing so will damage the mirror fixture and void the warranty
L
LINE
Color Black
GROUND
Color Yellow with Green stripe
N
NEUTRAL
Color White
LIGHTED WALL MIRROR MOUNTING & WIRING INSTRUCTIONS
For Model: 945HW
~ Please turn to following page for next steps ~
6368 Clark Avenue, Dublin, CA 94568
925.245.9220 - fax: 925.245.9203 - 1.800.639.6864