Page 3
Kim Lighting • P.O. Box 60080 • 16555 E. Gale Ave. • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/369-2695
3. Back fill hole with sand/gravel or rock and soil for stability. Do not back fill with bark or vermicolite. Never install an
in-grade luminaire below the surrounding ground level.
4. Remove rough-in debris shield and set aside for
future use.
5. Remove splice compartment cover.
7. Pull supply conductors into splice compartment.
Make wire connections observing polarity, i.e.;
green-to-ground, white-to-common and black-to-
voltage, using water proof wire nuts. This
provides protection against circuit failure, should
water enter the junction box.
LIGHTVAULT
®
- LTV10, 20, 30, 40 Series
Installation Instructions
6. Seal all around wires and conduit openings inside
splice compartment with RTV sealant to prevent
moisture from entering through the conduit system.
Sealant Tip: If required, the nozzle can be
extended by placing a small diameter tube or
hose on the end.
ROUGH-IN SECTION: Make certain electrical supply is OFF before starting fixture installation.
!
Rough-InHousing Installation cont'd.