K1: OFF/K2: OFF Auto conversion by default
K1: OFF/K2: ON 1280x720@60Hz
K1: ON/K2: OFF 1920x1080@60Hz
K1: ON/K2: ON 80 0x600@60Hz
CVBS(AV) need to set by remote controller, cannot be selected by K1&K2
combination.
4)
Image ratio adjustment
CV180 adopts "Stretch" mode for conversion output by default. It is applicable to
normal situation. However, if the input video signal is 576i 4:3 or 480i 3:2, and you
want to convert it to 720p/1080p 16:9
,
after stretching, the video will be distorting.
Vice versa, if you convert 16:9 video to 4:3 or 3:2. In this case, you can select
"Picture mode →Fit option by remote control menu, or "Stretch" mode to adjust. In
the maintaining ratio mode, there will be added black padding border around the
video.
5)
Prompt & Screen
CV180 converter comes with video input and output format information by default. If
you want to turn off the prompt, please select "prompt & screen"
in
the remote-control
menu, and select "cancel prompt message". Otherwise, please select "Auto prompt".
When there is no SDI signal input, or the input signal format is incorrect, the output
will keep the last image for 10s by default. You can set the maintenance time or no
image maintenance by "image maintenance".
CV180 converter supports production auxiliary functions such as image safe area,
sound column, center cross, etc. You can enable or disable relevant functions freely.
6)
Color conditioning
The default values of brightness, contrast, saturation and hue are 128 (middle value),
and the value range is 0-255. Based on the middle value, increase/decrease the value
corresponding to the increase or decrease of brightness/contrast/saturation.
7)
Restore factory settings
You can restore the factory set by "Restore default” button on the remote control.
Kindly noted all the settings would be restored to the factory default.
When there are problems when output like the output interface does not display
properly, you can also use the remote controller aiming at CV180's IR receiver, press
POWER/RESET " button on the remote control. Hold for one second and repress the
"POWER/RESET" button to restore the factory settings.