2022
JUNE 2022 / Rev: 1.0
11. Confirm Inverter-Battery Communication
Confirming Inverter-Battery Communication
Before plugging into the inverter, please confirm you have followed the previous KiloVault®
HAB™ specific instructions. The communication cable plugs into the Battery/CANbus port on
the Sol-Ark. Only if the Sol-Ark communication card does not have a Battery/CANbus port -
such as on an older Sol-Ark inverter, plug into the 'RJ45 485' or 'RS485' port.
To confirm BMS communication, enable "BMS Lithium Battery 05" in the Sol-Ark battery setup
menu That will enable a "Lithium Battery Info" screen under the main Sol-Ark setup menu.
Click on the gear icon to reveal the Lithium Battery Info menu. If the battery is communicating to
the inverter, a line of battery data will appear across line 2 of the Sol-Ark menu. The other data
lines will remain 0s.
You can download documentation for the KiloVault HAB and HAB iT mobile app at: htps://
kilovault.com/kilovault-hab-series/.
You can download documentation for the Sol-Ark here-
https://www.sol-ark.com/.