Parts Description 

 

 

 

Selecting a Location 

Select a firm, vibration-free and horizontal location for the scale. Avoid locations with direct 
sunlight, excessive air currents, heat sources, or rapid temperature fluctuations. 

 

 

Power 

Connect the AC Adaptor to the AC mains supply. Connect the plug to the AC jack at the bottom 
of the scale as shown in the illustration below. The power outlet should be close to the scale and 
easily accessible. 

 

 

 

Battery Power 

The scale will automatically switch to battery operation if there is a power failure or the power 
cord is removed to provide uninterrupted scale operation. 

Note: 

When low                  battery is displayed, the scale will shut off after 30 seconds. 

 
CAUTION: 

Risk of explosion can occur if replaced with the wrong type or connected improperly. 
Do not disassemble, repair or otherwise manipulate the battery socket. 
Obey the local laws and regulations when disposing of the battery.   

LCD Display

 

Key Pad

 

Battery Indicator

 

Stainless Steel Pan

 

Summary of Contents for KWD 15K

Page 1: ...ION MANUAL E MAN08152022 Ce manuel est disponible en fran ais http www kilotech com K851240 KWD 15K 15kgx1g 30lbx0 002lb 480ozx0 05oz GTIN 888960512401 K851241 KWD 30K 30kgx2g 60lbx0 005lb 960ozx0 1oz...

Page 2: ...1 TABLE OF CONTENTS Introduction 2 Product Specification 4 OPERATION 5 MAINTENANCE 9 ERROR AND STATUS MESSAGE 10...

Page 3: ...ads or leave a permanent load on the platform This may damage the measuring system Do not place the scale upside down on the pan Do not open the scale Never attempt to make repairs yourself because th...

Page 4: ...hould be close to the scale and easily accessible Battery Power The scale will automatically switch to battery operation if there is a power failure or the power cord is removed to provide uninterrupt...

Page 5: ...les are warranted against defects in material and workmanship for a period of one 1 year for the scale and 3 months for the adapter from the date of purchase Please retain your receipt as proof of pur...

Page 6: ...o setting activated NET Display net weight Hold Display hold function Condition of battery Power supply connected Steady green light represents the battery is fully charged gram Currently chosen weigh...

Page 7: ...ess the ON OFF button Scale will display and then enters the active weighing mode To turn the scale off press the ON OFF button Zero Operation Setting When powering on the scale and if the weight on t...

Page 8: ...e next digit Repeat until all the digits are correct Press HOLD TARGET OK to confirm the setting of lower limit and then enter to high limit setting HIGH LIMIT SETTING The first digit is displayed as...

Page 9: ...ously If the display shows Err this means weight exceeds overload limit SETTINGS Backlight Setting Press TARE and hold for 2 seconds to turn ON the backlight manually Press TARE and hold for 2 seconds...

Page 10: ...Y Scale will not turn on Battery discharged Check the battery or adapter Power cord not plugged in properly Check power cord connection and if plugged in properly into the power outlet Other failure H...

Page 11: ...service center Counting value is lower higher than the low limit value The scale has detected a problem with the load cell or wiring Have the scale serviced by KILOTECH authorized service center Zero...