15
Display Panel
+
Botch Count
Ignore Rundown Friction:
1. Press and hold “WS” button on the counter panel until “SE1”
shows up on the screen.
2. Press “Pc” button to prompt “SE2” on the screen, and use “Batch
Count” on the remote controller for setting.
3. The [uoF] is the level of thread setting from [u01] to [u99]. Adjust
forcing threads for your tightening needs. (ensured threads)
4. The [uoF] setting may cause “L” setting invalid when [uoF] thread
value is equal or greater than “L”.
uoF
Display Panel
+
Force
Thread Preset Setting:
1. Press and hold “WS” key button till “SE1” shows up.
2. Press “Pc” key button till “SE2” shows up and then setup “Force”
from remote control.
3. The [coF] is the level of thread setting from [c01] to [c99]. Adjust
preset threads for your tightening needs. The screwdriver will auto
shut off and appear OK when tightening has reached preset value.
coF
Display Panel
+
NG Confirm Setting:
1. Press and hold “WS” button on the counter panel until “SE1” shows up on
the screen.
2. Press “Pc” button to prompt “SE2” on the screen and use the “
” on
the remote controller for setting.
3. The [ncF] & [ncn] perform when NG shows up, system locks or unlocks
screwdriver.
4. The [ncF] is disable and the [ncn] is enable. The screwdriver will go to the
status of NG confirm when the value of impact setting is less than the
value of “L” setting.
5. To unlock screwdriver by releasing trigger and press “Res” button when
signs of a red LED keep on and buzzer keeps on briefly.
ncF
Display Panel
+
OK ALL Auto/Manual Settings:
1. Press and hold “WS” button on the counter panel until “SE1” shows up
on the screen.
2. Press “Pc” button to prompt “SE2” on the screen, and use “ ” on the
remote controller for setting.
3. The setting value is [AcF] [Acn], to set function based on needs.
4.
When set to [Acn], the screwdriver rotation behavior will be
prohibited when OK ALL occurred, then need to press the "Res"
button to confirm and functional resume.
AcF
Display Panel
+
Forward Fastened/Reverse Fastened Setting:
1. Press and hold “WS+Res” button until “SE3” shows up on the screen.
2. Use “
” on the remote controller for setting.
3. The setting value is [rrF] [rrn], to set function based on needs.
rrF