10
Other Cautions
1.
The best condition of using the tool is under 8 hours a day, do not over loaded.
according to operating frequency and torque loaded, we suggest adding lubricating oils in clutch
per 3-6 months, and kindly contact with distributor when product's maintenance .
2.
Do not attempt to repair or disassemble this cordless screwdriver without authorization. Always
have the device serviced by assigned factory or qualified person in order to have the warranty
effective continually.
3.
KILEWS is not responsible for any poor performance or damage caused by customers own
modification of the tool.
4.
It is necessary for the
management to have individual operators read and follow up all
instructions in this manual. Do not attempt to repair or disassemble this cordless screwdriver
themselves.
5.
Chemicals, Acetone, Benzene, Alcohol, Thinner, Ketone, trichloroethylene, etc shall not be in
contact with the surface of the screwdriver in order to prevent chemical damage.
6.
Please follow instruction carefully and do not drop or shock the screwdriver.
7.
This product allows you to adjust freely ( - ) and ( + ) to decrease and increase torque. Different
models will deliver different level of torque, when the torque is adjusted to the limit the switch
will not be able to turn, please do not force it or it will be damaged. High frequency of using this
power tool might cause overheating, please have the tool to be cool down properly.
8.
Not allow to turn the Hi/Lo switch during operation in order to cause system malt-function.
9.
The device will not be able to function again once the OK/NG indicator/signal is not turn off
yet.
10.
When adjusting the torque, for safety purpose should stop the screwdriver completely and set
the switch to neutral position. It could prevent the user from turning the tool on accidentally.
11.
During operation, the switch has been changed accidentally that the device will enable its
self-protecting mode which is power off. Re-start the tool when this happen.
12.
Each operational torque setting, using time and frequency may result in different level of wear
and tear, at higher torque setting and use extensively could accelerate the wearing down of tool.
After one month, the torque is getting reduce gradually at the rate of 2~3% or 3~5 %( max
torque). The longer use of the device, torque reduction will become stable and the users could
measure the torque by a tester on a regular time schedule to check if the torque power still meets
the criteria.
13.
SKC-PTA-L600/L450/L300 must be measured by the KILEWS torque meter KTM-1000.
SKC-PTA-L150F/L120 must be measured by the KILEWS torque meter KTM-250.
SKC-PTA-L80F/L70/L50F must be measured by the KILEWS torque meter KTM-150.
Slow speed
(rpm)
operation
frequency
Slow speed
(rpm)
operation
frequency
Slow speed
(rpm)
operation
frequency
900
1.0 ON 3.0 OFF
600
1.0 ON 3.0 OFF
300
2.0 ON 5.0 OFF
850
1.0 ON 3.0 OFF
550
2.0 ON 5.0 OFF
250
2.0 ON 5.0 OFF
800
1.0 ON 3.0 OFF
500
2.0 ON 5.0 OFF
200
2.0 ON 5.0 OFF
750
1.0 ON 3.0 OFF
450
2.0 ON 5.0 OFF
150
2.0 ON 5.0 OFF
700
1.0 ON 3.0 OFF
400
2.0 ON 5.0 OFF
100
2.0 ON 5.0 OFF
650
1.0 ON 3.0 OFF
350
2.0 ON 5.0 OFF
Slow speed Duty Cycle Conversion (for reference)
Based on 1000 rpm, 1 second ON/3 seconds OFF. For example, the duty cycle for 350rpm,
1000-350=650
,
650/1000%=65%
ON= 1*1.65= 1.65
,
OFF =3*1.65 =4.95 (rounded value) =2 seconds ON / 5 seconds OFF