Screwdriver Slow Start Control Box 

User Operation Manual

 

 

 
 

 
 
 
 
 
 
 
 
 

Model : KL – SSBN(BC6P&DC6P)

 

                                     

(Ver 1.0) 

 

 

 
 
 
 
 
 
 
 
 
 
 

  

 

   KILEWS INDUSTRIAL CO., LTD.

 

http://www.kilews.com

 

Y2F124-5-006

        

Summary of Contents for BC6P

Page 1: ...Screwdriver Slow Start Control Box User Operation Manual Model KL SSBN BC6P DC6P Ver 1 0 KILEWS INDUSTRIAL CO LTD http www kilews com Y2F124 5 006 ...

Page 2: ......

Page 3: ...n of Kilews Industrial Co Ltd Information provided in this manual is intended to be accurate and reliable However Kilews Industrial Co Ltd Assumes no responsibility for its use nor for any infringements upon the rights of third parties whitch may result from this use Acknowledgements KL SSBN BC6P DC6P is a trademark of Kilews Industrial Co Ltd BN is a series brushless screwdriver model with new co...

Page 4: ...nication interface KL SSBN BC6P DC6P provide slow start function to improve screw tightening quality under manual operation KL SSBN BC6P DC6P provide three digital output lines to output start brake and reverse signals to external device All output signals use MOSFET relay output to support mostly PLC interface KL SSBN BC6P DC6P is the best choice for screwdrivers apply to integrate with PLC in au...

Page 5: ...r supply model 4 KL SSBN BC6P DC6P support another alternative KILEWS standard anti EMI cable 3M to connect to BN series screwdriver it can reduce electromaganetic interference 5 Please connect KL SSBN BC6P DC6P to screwdriver then connect to power supply 6 KL SSBN BC6P DC6P is designed to operation only with the KILEWS BN BC6P series brushless screwdriver If connect to the old BC series brushless...

Page 6: ... COM Pin 4 3 When screwdriver run reversed output signal to Pin 3 and COM Pin 4 2 3 Pin assignment description Pin No Function I O Loop Interface 1 Start Output Output MOS Relay 2 Brake Output Output MOS Relay 3 Reverse Output Output MOS Relay 4 COM Common for output 2 4 Relay output wiring diagrams Regulate the spike voltage generated on the inductive load as follows MOS Relay output circuit max ...

Page 7: ...ter setting mode LED display RC 2 Press both button for 1 Sec to change to set next function 3 LED display RC SP Exit 4 Screwdriver control will be disabled and the power light will flash each 5 Sec between setting mode 5 Use or button to change the setting value RC Slow start time 0 0 9 9 Sec SP Slow start speed level L0 L9 4 Slow Start Switch 1 Toggle this switch to disable or enable RC SP funct...

Page 8: ...ry Over Temp Protection 1 Screwdriver will stop when the operation temperature is higher 2 LED will display E4 to indicate Over temperature protection 3 Screwdriver will disable 10 sec then automaic recovery Stall Protection 1 Screwdriver will stop when motor is abnormal stalled after start 2 LED will display E5 to indicate stall protection 3 Screwdriver will disable 10 sec then automaic recovery ...

Page 9: ...BN Series 7 4 Techical Diagram ...