PWX
119
Variable Internal Resistance Feature
7
Fa
ctory Option
Variable range
Rint: Internal resistance
0 =<Rint =<Rint (max)
The maximum internal resistance that can be set from the front panel during parallel opera-
tion is the value obtained by dividing Rint (max) during standalone operation by the number of
units in parallel operation.
The resolution is the value obtained by dividing the resolution during standalone operation by
the number of units in parallel operation.
Specifications
l
PWX750LF
PWX750MLF
PWX750MHF
PWX750HF
Rint (min) [
Ω
]
0.0001
1
1.
When the value is set from the front panel, the least significant digit is not shown on the
panel display.
The value varies at a higher resolution than what is shown, and the least significant digit
is rounded and shown in the next higher digit.
0.001
0.01
0.1
Rint (max) [
Ω
]
0.4000
2.857
23.00
185.7
Resolution [
Ω
]
0.0001
0.001
0.01
0.1
PWX1500L
PWX1500ML
PWX1500MH
PWX1500H
Rint (min) [
Ω
]
0.0001
0.001
0.01
0.1
Rint (max) [
Ω
]
0.2000
1.429
11.50
92.9
Resolution [
Ω
]
0.0001
0.001
0.01
0.1
PWX750LF
PWX750MLF
PWX750MHF
PWX750HF
Maximum internal resistance
that can be set
Rint (max) [
Ω
]
0.400
2.857
23.00
185.7
PWX1500L
PWX1500ML
PWX1500MH
PWX1500H
Maximum internal resistance
that can be set
Rint (max) [
Ω
]
0.200
1.429
11.50
92.9
Summary of Contents for PWX1500H
Page 10: ...10 PWX This page is intentionally blank...
Page 26: ...26 PWX This page is intentionally blank...
Page 88: ...88 PWX This page is intentionally blank...
Page 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 92: ...92 PWX This page is intentionally blank...
Page 120: ...120 PWX This page is intentionally blank...
Page 121: ...Appendix A Options B Troubleshooting...