52
PMC-A
Maximum number of power supplies connected in
series
The number of power supplies that can be connected in series
depends on the output voltage of the model and the isolation
voltage. Be sure the total output voltage of the power supplies
connected in series does not exceed the isolation voltage. For
the isolation voltage of each model, see the specifications.
Example In the case of the PMC35-3A, the isolation voltage
is 250 V. Therefore, the calc
u
lation gives 250/35 =
7.14 which means that
u
p to seven power s
u
pplies
can be connected in series.
4.7.1
Functions during Series operation
The functions of the PMC-A during series operation are as fol-
lows.
■
Voltmeter and Ammeter
For the total output current, sum the each units.
■
Remote Sensing
Can not be used.
■
External Control
Can not be used.
■
External Monitoring
・
Possible electric shock while the external moni-
toring is performed. When monitoring the output
voltage or current during series operation, the
common electric potential of the monitor signal
is different between each unit.
WARNING