4-8 Names and Functions of Parts
PLZ-4W
+CV
Pressing this key while holding down the SHIFT key (SHIFT+MODE) adds con-
stant voltage mode (+CV) to CC mode or CR mode.
When in CC mode, this operation switches the mode to CC+CV; when in CR mode,
this operation switches the mode to CR+CV. The current mode is indicated on the
display.
[7]
SET/VSET/MENU key
SET/VSET
Enters the basic setting (current, conductance, voltage, or power). This key illumi-
nates when you can change the basic setting.
In CC+CV mode, current and voltage are selected alternately each time you press
the key. In CR+CV mode, conductance and voltage are selected alternately each
time you press the key.
MENU
Pressing this key while holding down the SHIFT key (SHIFT+SET VSET) shows the
menu setup screen for setting the functions of the PLZ-4W and changing the settings.
•
For details, see section 5.13, “Menu Setup.”
[8]
RANGE/VRANGE key
RANGE
Switches the current, conductance, or voltage range according to the operation
mode.
Pressing the RANGE key when the load is turned off shows the range pop-up menu.
Each time you press the RANGE key while the menu is displayed, the range
switches in the order L, M, and H. You cannot select the range when the load is
turned on or when the short function is enabled.
VRANGE
Pressing this key while holding down the SHIFT key (SHIFT+RANGE) switches
the voltage range.
Pressing the VRANGE (SHIFT+RANGE) key when the load is turned off shows the
range pop-up menu. Each time you press the VRANGE (SHIFT+RANGE) key while
the menu is displayed, the range switches in the order 15 V and 150 V. You cannot
select the range when the load is turned on or when the short function is enabled.
[9]
SLEW RATE/SHORT key
SLEW RATE
Sets the slew rate value. This key illuminates when you can change the slew rate.
You cannot select the slew rate in CV or CP mode.
•
For details, see section 6.4, “Setting the Slew Rate.”
SHORT
Pressing this key while holding down the SHIFT key (SHIFT+SLEW RATE) sets or
clears the short function. A short icon is displayed while the short function is
enabled. You cannot select the short function in switching, CV, or CP mode.
•