30
Operation Manual
PFX2731S
Operation and Protection Functions | Panel Display
1
Stop the test from BPC 4000, and check that current is not flowing through the DUT.
The CHARGE/DISCHARGE/REST LED lights orange.
2
Remove the DUT.
3
Turn the POWER switch off (
○
).
Panel Display
When you turn on the power switch, the LEDs on the front panel will light up to display the channel
operating status. Every channel has LEDs to display the operation status.
LED color
Panel display
Description
Green
POWER
Power on (Tests are executable.)
Orange
STANDBY
Testing in pause (standby state)
Red
CHARGE
Charging in progress
Green
DISCHARGE
Discharging in progress
Orange
REST
Charging/discharging in pause
Red
CC
Constant current (CC) in progress
Green
CV
Constant voltage (CV) in progress
Orange
CP
Constant power (CP) in progress
Red
ALARM
Operation aborted due to a detected
alarm
ALARM (blinking)
Abnormality caused by hardware is
detected
Orange
WARNING
Protection function activation warning
- state that the protection function
goes into action upon execution a test
Red
HARDWARE PROTECT Hardware protection detected
CHARGE /
DISCHARGE /
REST
ALARM / WARNING
CC/CV/CP
HARDWARE PROTECT
POWER
/
STANDBY
Summary of Contents for PFX2731S