PFX2512
Selecting the Display
You can use the SELECT key on the front panel to select the value to show on the display.
The display switches in the following manner each time you press SELECT.
When you turn the power off and then back on, the display returns to show the voltage.
Overview of External Control
In addition to controlling the PFX2512 from the front panel, the EXT CONT terminal on the rear
panel can be used to perform the following controls.
•
External monitoring of the operating status
•
Alarm input using an external contact
The maximum ratings for each signal terminal are as follows:
•
Maximum voltage: 30 V
•
Maximum current (sink): 8 mA
Panel display
Display details
VOLTAGE (V)
Voltage.
CURRENT (A)
Current.
CAPACITY (Ah)
DUT (battery) capacity
ELAPSED TIME (h-min)
Elapsed time of the running cycle
CYCLE NO.
The display blinks during a test cycle or predischarge.
PROTECT (V)
Displays the H_OVP and H_UVP preset voltages alternately
ADDRESS
Displays, in order, the connection method, IP address, and channel
number of the LAN interface
SELECT key
DISPLAY area
Example of voltage display selection
CURRENT (A)
VOLTAGE (V)
ELAPSED TIME
(h-min)
CAPACITY (Ah)
CYCLE NO.
PROTECT (V)
ADDRESS
Lit green
The display switches every time you press
SELECT, and the LED for the displayed item
lights green.
You can return to the voltage display from any
display by holding down the key.
Hold down to return
to the voltage
display.
Summary of Contents for PFX2500 Series
Page 12: ...12 PFX2512 This page is intentionally blank ...
Page 62: ...62 PFX2512 This page is intentionally blank ...
Page 71: ...Specifications This chapter provides the PFX2512 s specifications and outline drawing ...
Page 96: ...96 PFX2512 This page is intentionally blank ...
Page 140: ...140 PFX2512 Troubleshooting This page is intentionally blank ...
Page 143: ......