3.2
Turning On the Power
This section describes the procedure for turning on the power. No load current will
flow if the PCZ1000A is turned on with its factory default settings. To allow a load
current to flow, the PCZ1000A needs to be set to load-on mode.
• Allow at least five seconds between turning the POWER switch on or off.
In-rush current of up to 80 A can occur at power on. Turning the POWER
switch on and off repeatedly during a short interval can result in the blown
input fuse.
Turning on the POWER switch
1
Check that the POWER switch is OFF ( ).
2
Check that all wiring connections are properly connected.
3
Turn the POWER switch to ON ( ).
4
Check the firmware version on the front panel display.
The front panel display shows the model name and firmware version.
The front panel display changes after approximately 2 seconds.
The upper part indicates the RMS current (Ar), peak current (Ap), and RMS voltage
(V) supplied to the load terminals of the PCZ1000A. The lower part shows the
operation mode (the above example shows "I SET" which indicates constant current
mode) and the setting (0.00 A in the above example).
When the POWER switch is turned on for the first time after purchase, the
PCZ1000A will start up in its factory default state.
■
When an error occurs
In case the calibration data is changed to the abnormal value caused by deterioration
of the internal memory and the like, "xx xxx EPPDATA ERR" ("x" may varies
depends on the contents of the error) is displayed with the buzzer sounds when the
POWER switch is turned on . It will return to the normal display in three seconds,
however, the error for the setting value and the ammeter/voltmeter may become
large because of the calibration data is not properly confirmed.
• If the PCZ1000A is used while the error is occurred, it causes the failure.
Contact your Kikusui distributor/agent for repairs.
See
CAUTION
See
PCZ1000A
Ver. 1.00
0.00Ar 0.0Ap 0.0V
-- ISET 0.00A --
See
CAUTION
Summary of Contents for PCZ1000A
Page 4: ...ii PCZ1000A This page is intentionally blank ...
Page 17: ...General Description This chapter gives an overview and describes the features of the PCZ1000A ...
Page 35: ...Operation This chapter describes each mode and function of the operation ...
Page 82: ...5 4 PCZ1000A This page is intentionally blank ...
Page 83: ...Specifications This chapter gives the specifications and dimensions of the PCZ1000A ...
Page 88: ...6 6 PCZ1000A This page is intentionally blank ...
Page 89: ...The appendix contains the basic operating modes operating range and troubleshooting Appendix ...
Page 99: ......