KIKUSUI Electronics Corp.
170
[SOURce:]FUNCtion Command
FUNC:BANK
Specifies the number of the waveform bank that you want to execute.
This command is invalid when the sync function is enabled (FREQ:SYNC ON).
This command is invalid if the compensation function is set to the soft sensing func-
tion or the regulation adjustment function (VOLT:COMP:MODE SOFT|RADJ).
If the signal source is set to external signal source (VOLT:EXT:EXTDC:SIGN:SOUR
EXT), this command is invalid.
Command
[SOURce:]FUNCtion[:SHAPe]:BANK[:INDex] <NR1>[,(@chanlist)]
[SOURce:]FUNCtion[:SHAPe]:BANK[:INDex]? [(@chanlist)]
Parameter
Value 0 to 256 (The default value is 0)
Settings are reset to default values when an *RST command is sent.
Example
FUNC:BANK 5
Response: NR1