KIKUSUI Electronics Corp.
130
PROG:EDIT:PHAS:UW
Sets the U-W phase difference of the sequence step.
Use PROG:EDIT:PHAS:RAMP to set the phase signal change.
This command is valid for three-phase output.
Command
PROGram:EDIT:PHASe:UW <step_NRf>,<enable_boolean>,<phase_NR3>
PROGram:EDIT:PHASe:UW? <step_NRf>
Parameter
<step_NRf>
Value: 0 to 599 Number of the step that you want to configure
Parameter
<enable_boolean>
Value:
ON(1)
Enables U-W phase difference control
OFF(0) Disables U-W phase difference control (default)
Parameter
<phase_NR3>
Value:
0.00 to 360.00
U-W phase difference (The default value is 0)
Unit:
DEG
Example
PROG:EDIT:PHAS:UW 1,ON,90
PROG:EDIT:PHAS:UW? 1
Response
Returns the U-W phase difference of the specified step in the following order.
U-W phase difference control enabled/disabled<NR1>, U-W phase differ-
ence<NR3>