Interface Setup
Interface Setup for PCR-M series
RS232C (standard equipped)
RS232C connection
Turn off the POWER switch on the PCR-M and the computer.
Use a D-sub 9-pin female-to-female AT type crossover cable for the RS232C cable. Figure
shows the connector pin assignments.
The KPM1000 does not use hardware handshaking (Crossover cable example2).
9-pin AT type connector
RS232C configuration
1.
Press CONFIG until the interface is set to "IntF."
2.
Turn the rotary knob to set RS232C to "232."
3.
Press CONFIG to set the baud rate to "bAUd."
4.
Turn the rotary knob to set the baud rate.
You can set the baud rate to 1.2, 2.4, 4.8, 9.6, or 19.2 (the unit is kBPS).
5.
Press CONFIG to set the flow control to "F.CTL" (Xon/Xoff).
6.
Turn the rotary knob to select "ON" or "OFF."
7.
Wait at least 5 seconds, and then turn the POWER switch off and on.
The settings are applied.
Introduction
Installing the VISA library
Interface Setup
Overview of Command
Parameters
Default settings
Command (function
search)
IEEE488.2 Common Commands
Output Setting
Protection and Clearing Alarms
Triggered Control of Output
Output On/Off Phase Control
Measured Value Queries
System Configuration
Registers
Command (ABC search)
Command (Sub-system
search)
SOURce
OUTPut
MEASure and FETCh
TRIGger
SYSTem
STATus
IEEE488.2 Common Commands
Other Commands
List(PDF)
Register
Architecture
Register structure
Appendix
A List of Errors
Processing time of main
Tutorial
Programming AC Output
Programming DC Output
Triggering Output Change
Output-on Phase Control
Measurement
Waiting for Operation Complete
Panel display
Status Monitoring
Error Checking
Visual Basic 2008
AC Power Supply PCR-M series
Communication Interface Manual
PCR-M series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.
72/166