PAN-A
1-13
Chap
.1
Setup
1
PAN35-20A(MODEL 700W)/MODEL 1000W
• To prevent electric shock, turn OFF the switch on the
switchboard (to cut off the power feed from the
switchboard) and then connect the AC power code.
• Inside the unit, protective circuits including input
fuses are connected in order to meet the input termi-
nal rating. Con
fi
rm that the wires of the speci
fi
ed
color are connected to the corresponding terminals
(L, N, and
(GND)).
• For applying power, use the AC power cord provided with the
product. Connection of the AC power code to the switchboard
must be carried out by quali
fi
ed personnel.
1. Attach crimp terminals to the wires of the AC power code.
2. Turn OFF the switch on the switchboard.
3. Connect the AC power code to the switchboard.
Fig.1-11
AC power code (AC power source side)
WARNING
CAUTION
NOTE
N:
White or blue
L:
Black or Brown
(
GND
)
:
Green or Green/Yellw
Summary of Contents for PAN 110-1.5A