Handling Precautions

„

„

Handling of the U, V, and W phase Boards

•  Ground yourself by touching a grounded metal object before 

touching the board.

•  Avoid handling the interface board in an environment subject to 

strong static electricity.

•  For storage, provide electrostatic protection measures such as 

the anti-static bag accompanying the interface board.

•  Do not drop a board or subject it to other impact.
•  Do not install or uninstall the interface board with the power ON 

of the PCR-LE Series.

„

„

Handling of the connecting and power-sync cable

•  Do not damage the cable.
•  Do not pull, bend, or apply any other stress to the cable.

Precautions When Moving the PCR-LE

Disconnect the cable(s) when moving the PCR-LE series to the 
installation location or when transporting the PCR-LE. Moving a 
PCR-LE series with a cable connected to the phase board may 
result in breakage of the cable or connector.

Installing the board on the PCR-LE

The 3P05-PCR-LE can be installed by inserting the U, V,  and W 
phase boards into SLOT1 of the three PCR-LE series, respectively.

 

Check that the POWER switch of PCR-LE is off.

 

Touch a grounded metal object (for example, the 

metal parts of the PCR-LE rear panel) to discharge 

any static electricity from your body.

 

Remove the screws that are holding the SLOT 1 

cover in place on the rear panel, and remove the 

cover from the panel.

 

Hold the panel parts of the board so that the printed 

circuit board side is facing up.

 

Insert the board into the slot so that the printed cir-

cuit board's connector is inserted into the connec-

tor at the back of the slot.

 

Insert the board all the way into the slot.

 

Use the screws that you removed in step 3 to fix the 

board in place in the panel.

 

Follow the same procedure to install the other two 

boards.

This completes installation of the phase board.

When a 3P05-PCR-LE has been inserted into the slot1 of a PCR-
LE series, that power supply can be used only in a three-phase 
system. To use the power supply in a single-phase system, the 
phase board must be removed from the slot1.

Connecting the bords

Use the connecting cable to connect the boards.

Connect the V-phase

U-phase board

Connect the W-phase

Connect the U-phase

3PHASE  DRIVER

3P05-PCR-LE

V-Phase board/

W-phase board

3PHASE  DRIVER

3P05-PCR-LE

TO V PHASE

TO V PHASE

FROM U PHASE

 

Check that the POWER switch of PCR-LE is off.

 

Place the three PCR-LE as close to each other as 

possible.

Arrange them so that no stress is applied to the connect-
ing cable. A PCR-LE power supply with the U phase board 
installed plays the role of the master unit that controls other 
power supplies.

V

U W

For the connection as shown below, you need the optional 
connecting cable (150 cm/ 280 cm). To perform parallel three-
phase operation, place the U phase to the center.

U V W

 

Connect the “TO V PHASE“ of U-phase unit and the 

“FROM U PHASE“ of V-phase unit firmly with the 

connecting cable using a screwdriver.

Do not remove the attached core from the cable. If you do, 
reattach it (be sure to wrap the cable around the core once (2 
turns)).

 

Follow the same procedure to connect the “TO W 

PHASE“ of U-phase unit and the “FROM U PHASE“ 

of W-phase unit with the connecting cable.

Do not remove the attached core from the cable.
This completes connection of the bords.

Operation Check

Check the operation of the PCR-LE series before you perform 
three-phase operation. 
Check the following items with no load connected. For detail of 
settings, see the PCR-LE series operation manual.

POWER switch ON
Voltage setting
OUTPUT ON/OFF
Voltage-range switching

If a trouble is occurring on even one unit, you will not be able to 
perform three-phase operation.

Summary of Contents for 3P05-PCR-LE

Page 1: ...r sync cable 1 m 2 pcs 91 80 5099 Connecting cable 75 cm 2 pcs Cable 91 80 9919 Core 96 00 0530 Setup Guide This guide 1 pc V and W phase boards one each The indications V and W on the panel part of each board Firmware version of PCR LE When using the 3P05 PCR LE the PCR LE must be required with the firmware version of 2 00 or later If the firmware ver sion of the PCR LE is 1 99 or previous versio...

Page 2: ...ow the same procedure to install the other two boards This completes installation of the phase board When a 3P05 PCR LE has been inserted into the slot1 of a PCR LE series that power supply can be used only in a three phase system To use the power supply in a single phase system the phase board must be removed from the slot1 Connecting the bords Use the connecting cable to connect the boards Conne...

Page 3: ...ngle core wires that are used to connect to the load Nominal cross sectional area mm2 AWG reference cross sectional area mm2 Allowable current A at Ta 30 C 86 F 0 9 18 0 82 17 1 25 16 1 31 19 2 14 2 08 27 3 5 12 3 31 37 5 5 10 5 26 49 8 8 8 37 61 14 6 13 3 88 22 4 21 15 115 1 Excerpt from Japanese laws related to electrical equipment The values vary depending on conditions such as the wire cov eri...

Page 4: ...rminal Master U phase W phase 2 m or less from the slave unit s L N to the master unit s L N 2 m or less from the slave unit s L N to the master unit s L N 2 m or less from the slave unit s L N to the master unit s L N Relay terminal Relay terminal PCR LE OUTPUT G N L OUTPUT G N L OUTPUT G N L OUTPUT G N L V S U R N W T G OUTPUT G N L OUTPUT G N L ...

Page 5: ...f the switchboard Power ON 1 Check that the POWER switches of PCR LEs are off 2 Use the power sync cable to connect the J1 connec tor and the J2 connector on the PCR LE rear panels Do not connect two J1 connectors to each other or two J2 connectors to each other Insert the cable firmly into the connectors until the are locked in place PCR LE Power sync cable V phase U phase W phase 3 Set the POWER...

Page 6: ...ed when you are setting three phase output 环境保护使用期限 Environment friendly Use Period 该标记为适用于在中华人民共和国销售的电子信息产品的环境保护使用期 限 只要遵守有关该产品的安全及使用注意事项 从制造年月起计算 在 该年度内 就不会对环境污染 人身 财产产生重大的影响 产品的废弃请遵守有关规定 产品的制造年月可以在以下网址中确认 http www kikusui co jp pi 毒有害物质或元素名称及含有标示 Name of hazardous materials and symbol of elemet in the equipment and quantity 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 本表格依据 SJ T 11364...

Reviews: