Important Information on Product Safety

Safety instructions

This document contains information on installing and commissioning the product “Z45FK, Z46FK, 
Z47FK, Z60FK”. Each person who carries out work on this product must have read and understood 
this document. If you have any questions that are not resolved by this document, you can obtain 
further information from the supplier or manufacturer.
If the product is not used in accordance with this document, the protection provided could be 
impaired.
The applicable regulations must be observed when installing and using the devices. Within the EU, 
these include regulations regarding occupational safety and accident prevention as well as those 
from the VDE (German Association for Electrical, Electronic & Information Technologies). If the 
device is used outside of the EU, it is the responsibility of the plant engineer or operator to comply 
with local regulations.
Mounting, installation and commissioning work on the devices may only be carried out by qualified 
technicians. Qualified technicians are persons who are familiar with the described product and who 
can assess given tasks and recognize possible dangers based on their technical training, knowledge 
and experience, as well as their knowledge of the applicable regulations.

Symbol meanings

WARNING

Indicates a hazard of medium risk which can result in death or serious bodily injury if not avoided.

CAUTION

Indicates a hazard of low risk which can result in minor or medium bodily injury if not avoided.

!

CAUTION

Indicates a hazard which can result in material damage or malfunctions if not avoided.

NOTE

Indicates additional information that can simplify working with the product.

Notes on disposal

In accordance with the applicable laws and directives of the European Union countries, the product 
should not be disposed of with household waste. This ensures environmental protection and 
sustainable recycling or raw materials.
Commercial users should contact their supplier and observe the conditions of the purchase 
agreement. This device may not be disposed of together with other commercial waste.
The local and currently applicable laws must be observed.

Summary of Contents for Z45FK

Page 1: ...are fitted with spring terminals which make it possible to connect wires quickly and easily It is not necessary to use a tool to connect solid wires and litz wires with conductor end sleeves an ordina...

Page 2: ...mmissioning work on the devices may only be carried out by qualified technicians Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recogn...

Page 3: ...es Z46FK 2 000 000 switching cycles Display LED operating display Manual switch Z45FK Z46FK None Z47FK Manual switch at field level Z60FK Manual switch at field level with a poten tial free feedback c...

Page 4: ...05 Dimensions Connection ZxxFK Z43 250 V AC 6 A 1500 VA 11 A1 14 12 GN A2 Z45FK 14 24 12 22 11 A1 21 230 VAC 0 25 A 60 VA GN A2 Z46FK A1 A3 0 ON A3 AUTO OFF 11 A1 12 14 250 V AC 6 A 1500 VA GN A2 Z47F...

Page 5: ...c installation can cause death due to electric shock Mounting removal may only be carried out when power is switched off Comply with VDE guidelines and local wiring regulations when mounting removing...

Page 6: ...any further and it clicks into place in the spring terminal In the case of litz wires without conductor end sleeves the spring terminal must be opened using a slotted screwdriver Insert the screwdrive...

Page 7: ...oper place to make the cut Then insert the connecting bridge Z43 from the top or from the bottom into the contact slot and press it down WARNING Contact with live components of the building s electric...

Page 8: ...are switched at the output terminals In secondary earthed systems PELV this prevents any unwanted connection to ground or the reference potential and prevents an active signal from being generated at...

Reviews: