Product Description

RPW414P-FTL

Datasheet 1.10-65.040-01-EN

Issue 2017-04-10

Summary of Contents for RPW414P-FTL

Page 1: ...ce and an algorithm for self learning of utilization time profiles heating profiles in rooms Application Solar powered self learning room control module with LCD and smart commu nication management Fo...

Page 2: ...hing in the MD15 FTL radio partner on the RPW414P FTL 13 Mounting 14 Removal 16 Operating level 16 Setting the initial display 16 Setting the setpoint 16 Manually switching between comfort and economy...

Page 3: ...he applicable local regulations must be observed when installing and using the device Meaning of the symbols WARNING Indicates a hazard of medium risk which can result in death or severe bodily injury...

Page 4: ...his device contains a humidity sensor This humidity sensor is influenced by chemical substances in the air that can be produced for example due to the evaporation of cleaning and care products used to...

Page 5: ...er Integrated PIR Passive infrared sensor Integrated digital measuring transducer Measuring range Temperature Relative air humidity 0 50 C 20 80 Measuring tolerance Temperature Relative air humidity T...

Page 6: ...the radio partner is interrupted an internal resynchronization algorithm starts automatically Radio interference is indicated on the screen by corresponding icons see page 28 CAUTION This product use...

Page 7: ...ion shafts fire doors etc must be taken into consideration during planning CAUTION Elevated humidity increases natural signal damping NOTE Recommendation Plan radio paths horizontally on a single leve...

Page 8: ...n of RPW414P FTL the selected installation location can be changed and optimized at any time without additional effort The installation location must have sufficient lighting using the device in unlit...

Page 9: ...g To select the service level see page 25 06 Down arrow button To adjust reduce value 07 Selector button To select the display or menus 08 Occupancy button To switch between comfort mode economy mode...

Page 10: ...ted presence absence and vacation mode 10 Auto Learned utilization time profile is active automatic mode 11 Bars Shows the field strength of the receiving wireless signal in infor mation menu only 12...

Page 11: ...ting the installation location NOTE The Test installation location function remains active as long as the text InSt is displayed see page 12 The room control module switches off again if a radio partn...

Page 12: ...If a radio partner has not been taught in after 15 minutes the room control module automatically switches off NOTE If the energy storage unit is empty the Sun icon will not appear even if the locatio...

Page 13: ...seconds following completion of the teach in process Once all wireless small actuators have synchronized successfully after the teach in process the antenna symbol is also displayed after a further 4...

Page 14: ...ope of delivery of the room control module WARNING Flush mounted cabling and piping at the installation location electricity gas water Cabling and piping can be damaged by drilling Check the installat...

Page 15: ...ounting Flexible screw mounting 1 Bar 2 Adhesive numbers Wall mounting Flexible adhesive mounting with double sided transparent adhesive strips NOTE For a permanent connection remove any dust and grea...

Page 16: ...hange the current setpoint manually Briefly press the or button The setpoint to be set flashes Set the required setpoint using the or button The new selected value flashes for approx 5 seconds It is t...

Page 17: ...then active again and the Auto icon appears on the display Example 1 Comfort temperature 20 C economy temperature 16 C Room used 6 00 AM 9 00 AM and 3 00 PM 9 00 PM Absence set manually by pressing th...

Page 18: ...sary to adequately ventilate the room To save on heating costs there is also an option to have the wireless small actuator close the valve Press and hold the button for 5 seconds The window icon appea...

Page 19: ...repeatedly or the button to select the Conf function Hold down the Occupancy button for 5 seconds Release the Occupancy button The Set vacation menu item appears in the display Hold the Occupancy butt...

Page 20: ...Briefly press the Occupancy button repeatedly or the button to select the Conf function Hold down the Occupancy button for 5 seconds The Set vacation menu item appears in the display Briefly press th...

Page 21: ...European Time Setting the 12 24 hour display Hold down the Occupancy button for 5 seconds The text Menu briefly appears on the display followed by SETP Release the Occupancy button Briefly press the O...

Page 22: ...peatedly or the button to select the Conf function Hold down the Occupancy button for 5 seconds The Set vacation menu item appears in the display Briefly press the Occupancy button repeatedly or the b...

Page 23: ...other actions the display will return to the initial display after 5 seconds Status message The status message is displayed For more information see page 28 Display of the taught in radio partners If...

Page 24: ...int comfort mode economy mode or vacation mode Comfort mode setpoint Briefly press the Occupancy button or the or button to set the required setpoint The setpoint for comfort mode continues to flash w...

Page 25: ...y press the Setting button The room control module switches to the service level Briefly press the Occupancy button repeatedly or the button and the aforementioned functions will be offered one after...

Page 26: ...ible to connect to a Building and Energy Management System BEMS This makes it possible to generate additional functions such as Visualizing operating states Displaying trend curves e g for the room te...

Page 27: ...lt settings and switch off room control module function will run The room control module switches off The display disappears NOTE The taught in radio partners are then deleted and the room control mod...

Page 28: ...mall actuators Antenna Er01 On On Radio connection partly interrupted 1 hour At least one wireless small actuator is transmitting Antenna Er01 Off On Radio connection interrupted 1 hour No wireless sm...

Page 29: ...pear in the display more and more frequently it indicates that the AA lithium batteries need to be replaced This must be carried out by an authorized service technician Please contact your supplier Ra...

Page 30: ...ion is detected in the room control module the Er08 icon appears on the display The following troubleshooting procedures can be implemented Reset the room control module to the factory settings see pa...

Page 31: ...s monitored constantly If a system time malfunction is detected in the room control module the Er03 icon appears on the display Reset the time and date see page 20 The Er03 icon disappears from the di...

Page 32: ...A Page 32 32 Product Description RPW414P FTL Datasheet 1 10 65 040 01 EN Issue 2017 04 10...