Product Description

MD15-FTL-HE, MD15-FTL-OV

Datasheet 3.09-20.315-01-EN

Issue 2017-01-09 Rev 1

Accessories (not included in delivery)

Adapters for radiator valves with 

MD15-FTL-HE

 radio small actuators

Dimensions

MD15-FTL-HE, MD15-FTL-OV

Z220

Protective battery cover for MD15-FTL-xx

VS3

Anti-vandalism protector for MD15-xx-HE

Item no.

ID

Type

Z800

9703-24

Danfoss series 2 - 20 x 1

Z801

9704-24

Danfoss series 3 - 23.5 x 1.5

Z802

-

Danfoss RA2000

Z803

9800-24

Danfoss RAV

Z804

9700-24

Danfoss RAV-L

Z805

9700-27

Vaillant Ø 30 mm

Z806

9701-28

TA (M28 x 1.5)

Z807

9700-30

Herz (M28 x 1.5)

Z808

9700-55

Comap (M28 x 1.5)

Z809

9700-10

Oventrop (M30 x 1)

Z810

9700-33

Giacomini

Z811

9700-36

ISTA (M32 x 1)

Z812

9700-32

Rotex (M30 x 1) 

Z814

9700-34

Uponor (Velta) valves

Z815

9701-34

Uponor (Velta) Provario 

Z816

9700-41

Markaryd

85

47

71,5

62,5

91,5

M30x1,5 DIN 13 (MD15-FTL-HE)

M30x1 DIN 13 (MD15-FTL-OV)

Summary of Contents for MD15-FTL-HE

Page 1: ...ntrol in heating systems The actuator is radio controlled based on the non proprietary EnOcean radio protocol The following EnOcean Equipment Profile EEP is supported EEP A5 20 01 Battery Powered Actu...

Page 2: ...taller or operator to comply with local regulations Mounting installation and commissioning work on the devices may only be carried out by qualified technicians Qualified technicians are persons who a...

Page 3: ...t settings Measuring system Integrated digital temperature sensor 0 40 C 0 5 C at 25 C Interfaces EnOcean radio interface Radio telegram EnOcean radio telegram bidirectional EEP A5 20 01 Battery Power...

Page 4: ...no ID Type Z800 9703 24 Danfoss series 2 20 x 1 Z801 9704 24 Danfoss series 3 23 5 x 1 5 Z802 Danfoss RA2000 Z803 9800 24 Danfoss RAV Z804 9700 24 Danfoss RAV L Z805 9700 27 Vaillant 30 mm Z806 9701...

Page 5: ...actual value and the integrated control function of the actuator With external operator panel EnOcean technology Using the operator panel the users can freely determine the setpoint or enter their ow...

Page 6: ...the radio partner is checked Performing a communication test has no effect on the transmission reception interval see p 20 Energy block automatic Window open recognition When a window is open the flow...

Page 7: ...ode according to the method of control from the radio partner actuator mode or self controlled mode NOTE If the communication with the radio partner is disrupted the emergency mode status bit self con...

Page 8: ...N Bit 0b0 Teach in telegram 0b1 Data telegram DB_0 BIT_2 Self controlled mode 0b0 off 0b1 on DB_0 BIT_1 Not used DB_0 BIT_0 Not used Receive mode Commands from the controller to the actuator rx time m...

Page 9: ...hroughput R10E 10 10 1 25 3 8 R15E 15 10 1 35 1 2 R20E 20 10 2 5 3 4 Straight throughput R10DV 10 10 0 73 3 8 with Kvs setting R15DV 15 10 0 73 1 2 R20DV 20 10 0 73 3 4 Right angled throughput R10EV 1...

Page 10: ...mass flow rate The maximum flow rate Kvs value m h can be selected by using the settings 1 2 3 4 5 6 7 or 8 delivery setting 8 corresponds to a Kvs value 0 86 The setting can be made using a Z29 socke...

Page 11: ...a straight section of the pipe A distance of 10 times the nominal diameter is recommended between the valve flange and manifold or other similar parts The installation location is to be selected so t...

Page 12: ...tteries with the correct polarity When inserting the batteries observe the polarity as marked in the battery compartment Use only alkaline batteries type AA LR6 1 5 V NOTE After changing the batteries...

Page 13: ...rtment cover using the special key supplied by inserting it into the intended place Remove the cover The special key is included with delivery of the small actuator Inserting the batteries and close t...

Page 14: ...22 Product Description MD15 FTL HE MD15 FTL OV Datasheet 3 09 20 315 01 EN Issue 2017 01 09 Rev 1 Installing accessories Z800 to Z816 Z802 Z805 Z800 Z801 and Z806 816 ID 1 2 3 2 mm 4 5 6 7 8 ID 1 2 3...

Page 15: ...efore beginning work If necessary close the gate valve and turn off pumps After the pipeline has cooled off you can begin removal of the small actuator MD15 FTL HE MD15 FTL OV Open the battery compart...

Page 16: ...A Page 16 22 Product Description MD15 FTL HE MD15 FTL OV Datasheet 3 09 20 315 01 EN Issue 2017 01 09 Rev 1 Commissioning Overview of functions...

Page 17: ...s and functions of the MD15 FTL xx In addition to these instructions the product descriptions of other system components such as radio partners are to be observed The buttons and LED displays that are...

Page 18: ...ch in process was successful both visually status LED flashes green 2 times and acoustically 2 signal tones in succession An initialization run is automatically carried out Close the housing of the MD...

Page 19: ...ion path NOTE If the communication with the radio partner is interrupted for longer than 1 h the radio small actuator switches to emergency mode see page 5 and the emergency mode status bit self contr...

Page 20: ...hear 5 successive signal tones and the status LED flashes green 4 times and orange 1 time Release the push button 2 The new radio communication interval is acknowledged again both visually and acousti...

Page 21: ...ver NOTICE Insert the batteries with the correct polarity When inserting the batteries observe the polarity as marked in the battery compartment Use only alkaline batteries type AA LR6 1 5 V NOTE Afte...

Page 22: ...tteries in the household waste Dispose of used batteries at an approved collection point or store in accordance with legal regula tions or follow the applicable guidelines in your country for reducing...

Reviews: