Commissioning
GLT-R003-2HDSATA
R
Page 12 / 12
4.75-10.003-11-EN | 2019-11-12
Automatic restore function
Other possible situations
Cause
■
What happens if the energy supply of the computer is interrupted while the SATA
RAID system is automatically restoring the data?
Repair
■
If you are in mirror mode (RAID 1) and the energy supply is switched off during an
automatic restore process, the control automatically detects the percentage of the
restore process that is complete. When the energy supply is restored, the restore
process starts and continues automatically.
Cause
■
Is it possible that data may be lost during an automatic restore?
Repair
■
The data is copied from a sector of one drive to the sector of the other drive. When
the sectors are faulty, the system generates only a hypothetical duplication. The
saved data in the faulty sectors may be lost.
Cause
■
Why is the restore process slowing down?
Repair
■
Restoring and saving data on the computer system slows down the system until the
memory operations are complete.
Cause
■
How can I switch the buzzer on and off?
Repair
■
In its initial state when delivered from the manufacturer, the alarm buzzer is switched
on.
■
You can switch off the alarm buzzer by pressing the “Buzzer on/off” button.