Product Description

DDC111 and DDC111-2 room control modulel

Application

The room control modules are used together with the technolon® RCNxxx-L 
or FBR110-L room controllers. A room control module can be connected to 
each technolon® room controller.
DDC111-2 with LCD display for indication of room temperature and operating 
buttons for manual setting of the room temperature setpoint and switching 
between three fan levels.
The DDC111 room control module also has operating buttons for switching 
between day, night and stand-by modes. 

DDC111-2

DDC111

Content

Page

Important Information Regarding Product Safety ..................................................................................................2
Item........................................................................................................................................................................3

Technical Data.....................................................................................................................................................3
Accessories (not included in delivery) .................................................................................................................3
Dimensions ..........................................................................................................................................................4
Connection...........................................................................................................................................................4

Mounting ................................................................................................................................................................5
Operation ...............................................................................................................................................................6

DDC111-2 Operation ...........................................................................................................................................6
DDC111 Operation ..............................................................................................................................................7

Summary of Contents for DDC111

Page 1: ...oom control modulel Application The room control modules are used together with the technolon RCNxxx L or FBR110 L room controllers A room control module can be connected to each technolon room contro...

Page 2: ...perator to comply with local regulations Mounting installation and commissioning work on the devices may only be carried out by qualified technicians Qualified technicians are persons who are familiar...

Page 3: ...t in steps of 0 1 K Symbol display to indicate operating mode Fan levels DDC111 2 operating buttons button Switches to temperature mode for setting the room temperature setpoint button Switches to fan...

Page 4: ...ge 4 8 Product Description DDC111 DDC111 2 Datasheet 1 10 51 111 01 EN Issue 2012 05 09 Dimensions Connection 82 5 28 3 82 5 RJ9 DDC111 2 DDC111 RJ9 15 cm 0V 5V Tx Rx sw rt gr gl Z178 2 RJ9 10 m Z178...

Page 5: ...power is switched off The room control module can be mounted on the wall or onto a flush mounted box Choose an installation location that is subject to the air flow of the room to ensure that the room...

Page 6: ...odule automatically switches back to the standard display after 5 seconds The new room temperature setpoint is saved Switching fan levels on or off Fan levels are automatically switched on and off by...

Page 7: ...the room control module automatically switches back to the standard display after 5 seconds The new room temperature setpoint is saved Switching on day or stand by mode The central program automatica...

Page 8: ...ry fan levels can also be switched manually by the user Manual control Press the button The room control module switches to the manually adjustable fan mode The function symbol is displayed and the cu...

Reviews: