4. Installation / Mounting Instructions
OPTION 2:
Mounting on Other Surfaces
1. Choose a mounting location (wall
or ceiling) and using the mounting
plate provided as a template, mark
three-hole locations.
2. Install the three provided screws
through the mounting plate and
tighten. DO NOT over-tighten screws.
(If mounting in plasterboard or similar
surface, drill 3/16” holes and use the
plastic anchors provided.) Anchors
are not required for mounting on
hard surfaces such as wood.
Attaching And Activating The Alarm
This model is equipped with a feature that automatically activates the
alarm when the alarm is attached to the mounting plate for the first
time. Once activated, the battery will supply power to the alarm for the
life of the alarm (10 years) under normal conditions.
Align the alarm with the mounting plate and rotate clockwise (right)
approximately 45° until the unit stops and clicks into place. DO NOT
over-tighten. If unit needs to be re-aligned, rotate the alarm counter
clockwise, remove and rotate to desired alignment. NOTE: The alarm will
mount to the plate in three (3) positions (every 120 degrees).
You will know power has been supplied when alarm briefly chirps. Unit will
remain on until unit is disabled by the user at alarm’s end of life. Do not
over tighten the alarm as damage to alarm or mounting surface may occur.
The alarm is now activated!
After installation/activation, test your
alarm as described in Operation and Testing section.
Warning: Failure to properly install and activate this alarm
will prevent proper operation of this alarm and will
prevent its response to fire hazards.
Model P3010B-CA
will issue a voice prompt at activation asking the
user to press the test button. Proceed to Operation and testing section.